![background image](http://html1.mh-extra.com/html/franke/uvc-26/uvc-26_operating-instructions-manual_2326793007.webp)
UVC-System
Instruction manual
7
2. Installation
The installation must be performed by technical personnel in accordance with the manufacturer's specifications;
see the installation manual.
Carefully remove the protective foil from the external walls. Remove possible remaining adhesive with a suitable
solvent.
Clean the stainless-steel surfaces with a damp cloth (using lukewarm water and neutral soap), then wipe with
clean water and dry carefully.
Do not use sponges or water jets.
2.1 Obligatory instructions
The operator of UVC systems is obliged to operate the equipment according to these instructions for use. Perform
the prescribed periodic inspections and the prescribed verification and maintenance work.
If this obligation is not complied with, the warranty is invalidated.
Attention: In the absence of protection, UVC light is hazardous to humans (to the eyes
and skin).
Before opening the equipment, which also includes removing the Franke aerosol filters,
the UVC system must in all cases be switched off manually via the switch.
It is also obligatory to do this if the safety devices switch off the equipment automatically
during normal operation if an intervention into the equipment is performed.
Prerequisites for use as directed
This is a technical appliance exclusively intended for its working use.
The appliance may only be used for its intended purpose, i.e. for cleaning kitchen exhaust air
in conjunction with an extraction hood, exhaust air tubing system and an exhaust air ventilator
of the correct size.
Any other type of use is inappropriate.
The installation of the appliance must be performed by qualified technical personnel in
accordance with the manufacturer's specifications.
As a basic principle, the UVC system can / must only be started up when the ventilation
system is also switched on.
If the UVC system is opened by means of the special key via the locks
"I2"
countersunk into
the front plate, the control must be switched off beforehand via the
"C"
button; see Figure 2,
page 5. The top left of the display must read STANDBY or OFF.
The personnel must be informed and instructed in writing in this regard. Please read Section 4
concerning the operation of the control component.
The UVC system must only be operated with exhaust-air hoods intended for UVC
systems.
The exhaust-air hood must only be operated with aerosol filters (Franke SKKG, SKKF,
SKKB-type filters).
3. Connection instructions
3.1 Electrical connection
!
The appliance must be installed by a suitably qualified person in compliance with the
manufacturer's instructions.
!
!
!
!
!
!
!
!
!
!
!
!
!
Obligatory instructions:
The operation of kitchens and kitchen exhaust air equipment must only be performed with
Franke aerosol filters inserted in the universal hood. The UVC system must be switched
off before the filters are removed from the hood!
USA
USA