background image

15

Declaration of conformity

The Omni boiler complies in accordance 
with the following directives: 

2006/95/EC Low Voltage Directive
2011/65/EU RoHS Directive
2009/125/EC Eco Design Directive

Protection Level: IP20

The Omni boiler conforms to the 
requirements of the relevant EU guidelines.

The symbol on the product or on its 
packaging indicates that this product may 
not be treated as household waste. Instead 

it shall be handed over to the applicable collection point for the 
recycling of electrical and electronic equipment. 

By ensuring this product is disposed of correctly, you will help 
prevent potential negative consequences for the environment 
and human health, which could otherwise be caused by 
inappropriate waste handling of this product. 

For more detailed information about recycling of this product, 
please contact your local city offi  ce, your household waste 
disposal service or the shop where you purchased the product.

The Franke Omni 4

-

in

-

1 system is a product 

designed in 

conjunction with 

Greg Rowe Ltd

E

ngland, and is protected by 

the 

following patent applications 

GB1515295.2, GB1515293.7, EP15182884.5, US14/837,640, 
and in China.

NutRunna

® 

 

is a r

egistered trademark.

© Greg Rowe Ltd. All Rights Reserved

Summary of Contents for OMNI 4in1

Page 1: ...2 FRANKE OMNI 4in1 BOILING WATER SYSTEM Installation instructions...

Page 2: ...be between minimum 1 5 BAR 22 psi maximum 5 BAR 73psi Introduction This guide explains how to install a new Franke Omni 4in1 Boiling Water System Thank you for purchasing a Franke Omni Tap System In k...

Page 3: ...member Boiling water is potentially dangerous and great care should be exercised when using the Franke Omni tap The installation must be carried out by a suitably qualified professional in strict acco...

Page 4: ...t elbow 14 Tapered silicone washer for boiling water outlet red sticker 15 Flat silicone sasher for boiler water inlet green sticker 16 Vent assembly 17 Saddle clamp 18 Vent hose 19 Vent assembly elbo...

Page 5: ...over the hoses and the two studs at the base of the tap Screw the two clamp nuts 6 on to the studs using the box spanner 7 4 Check the alignment of the tap then tighten the two clamp nuts using the b...

Page 6: ...ing to eventual failure 1 Position the filter unit 21 vertically with the hoses at the top in its previously determined location 2 Mark the positions for the two filter unit support screws 24 using th...

Page 7: ...two black rubber inserts for 41mm waste pipe Leave them in place for 32mm pipe 3 Place the saddle clamp in position on the chosen section of waste pipe and re assemble the clamp Tighten the nuts and b...

Page 8: ...he nut firmly sufficient to make a watertight seal Do not overtighten 5 Take the push fit elbow 13 Connect the elbow to the grey push fit stem on the end of the vent flexible hose 18 black indicator P...

Page 9: ...er is discharging from the vent pipe Important note If water does not start to discharge from the vent pipe into the cup after 10 minutes switch off the power operate the boiling water function on the...

Page 10: ...Omni tap The Omni tap is manufactured in stainless steel and is therefore extremely durable and stain resistant All that is required to keep it in good condition is a regular wipe over with a damp clo...

Page 11: ...rtridge for the Franke Omni system is the Franke 08 The Franke 08 will remove sediment chlorine and other chemicals as well as prevent limescale from damaging the boiler It should be replaced every 6...

Page 12: ...issue check the water pressure using a gauge rather than estimating to ensue a reliable reading As previously stated it should fall between 1 5 bar 22 psi 5 bar 73psi If the problem persists remove t...

Page 13: ...bags will often remedy the problem Alternatively you can consider switching to a Franke 06 cartridge which will remove the calcium and magnesium however please note this filter will need to be change...

Page 14: ...air or replacement of a product that has failed for any of the following reasons Faulty installation repairs or alterations not in accordance with the installation guide Normal wear and tear Accidenta...

Page 15: ...electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by ina...

Page 16: ...l Street Cawston Norfolk NR10 4FE Phone 44 0 1603 875 468 Email info frankefilterflow com Franke UK Limited West Park MIOC Styal Road Manchester M22 5WB Phone 44 0 161 436 6280 Fax 44 0 161 436 2180 E...

Reviews: