 | OZO-FLO Troubleshooting Guide

Contents

No water flow / Faucet not functioning ........................................1
Not enough water flow .................................................................2
Too much water flow ....................................................................2
LED’s blinking once per second ....................................................2
LED’s blinking 2x per second........................................................2
LED not working ...........................................................................3
Water stops flowing out when washing hands ...............................3
Water does not shut off ................................................................3
Appendix 1 : Parts Breakdown ......................................................4

No water flow / Faucet not functioning 

a.  Cycle power by unplugging and plugging in transformer. The blue 

LED should blink once during power up. If the LED did not blink 

once, make sure green LED is illuminated on the power supply. 

If no green LED on power supply, make sure that the GFI has not 

tripped and there is power at the plug. 

b.  If power at the plug is confirmed and the green LED is not shown 

on the transformer, replace transformer (ZF120A-2402500-FKC). 

c.  If transformer has a green LED and the blue light blinks upon 

power-up but the faucet will not activate, check that the yellow 

sensor wire is connected properly.

d.  Activate the faucet by placing your hand in-front of the sensor 

(ensure that you are not wearing black silicone gloves as the IR 

signal will not bounce back if they are used). When activating 

the faucet, you should see the blue light ring illuminate as well 

as hear the solenoid valve click. If the blue light and the sole-

noid does not activate, replace PCB (AT00-190). If the blue light 

comes on but the solenoid does not click, ensure that both spade 

connectors are attached to the solenoid valve. If so, replace 

solenoid valve and re-test (AC17-104-6V).

e.  If after PCB replacement and solenoid replacement  the faucet 

still does not function, replace faucet body. 

Not enough water flow

a.  Ensure control stops are fully open.

b.  If using a mixing valve, ensure BOTH the hot and cold water sup-

plies are on. If the cold water supply is not active, the TMV will 

shut off or greatly restrict the hot water side as well. 

c.  Flow rate of ozo-flo is dictated by the outlet of the faucet. Using 

a wrench, unscrew the outlet and activate the faucet. This will be 

full line pressure. If flow rate (without the outlet) is still low, check 

for adequate flow rate prior to the mixing valve. 

d.  Blockages can occur in inlet screens of the mixing valve as well 

as the inlet of the solenoid valve (AC17-104-6V) in the wall housing. 

Too much water flow

a.  Water flow is controlled by the outlet of the faucet. Ensure that it 

is in place.    

LED’s blinking once per second

a.  This is an indicator that ozone is not being generated. 

b.  First verify that the blue banded cable is connected between the 

PCB and the cable going to the ozone generator. 

c.  Verify TDS is above 50. Normally the facility maintenance team 

would have this checked monthly. If the customer can not deter-

mine this, each rep agency has a small TDS meter that can be 

used; otherwise, a handheld programmer (AC01-005) can scan 

the system and estimate TDS.

d.  If TDS is acceptable and the cable is properly connected, there 

must be a break in the electrical connection to the ozone genera-

tor. Replace with item 0075-106745 and re-test. 

LED’s blinking 2x per second

a.  This is an indication of the ozone generator pulling too much 

current from the power supply. This can happen if there is a short 

in the ozone generator electrodes or when the water conductivity 

(TDS) is too high. 

b.  First verify that the TDS is below 350. If TDS is above, contact 

customer service to obtain a smaller ozone generator. 

c.  If TDS is in normal range (75-350) remove ozone chamber from 

the rear of the sink and inspect the mesh for any debris that 

could cause a short in between electrodes. 

d.  If no short is detected and the error is still occurring, replace with 

new ozone generator item 0075-106745.

LED not working

a.  Cycle power and observe if LED blinks once during power up. 

If LED illuminates then it has been set to 0 intensity using the 

handheld programmer AC01-005. Use the programmer to modify 

the LED intensity setting. 

b.  If the LED does not blink once during start-up, replace spout.  

TROUBLESHOOTING GUIDE 

OZO-FLO models HWF05, HWF23, HWF43

Summary of Contents for HWF05

Page 1: ... drain and trap free of CPOs and other pathogens This also improves the efficiency of hand washing Other control features include a post wash cycle of 3 seconds which ensures all soap residue and bacteria has been washed down the sink and a daily purge cycle to prevent stagnant water in the lines and ensure continuous waste disinfection Any standard P trap will be disinfected with this process Ozo...

Page 2: ...eration the concentration of ozone and other mixed oxidants are building in the chamber The faucet will slowly drip from the spout This is normal as the volume in the chamber is increasing due to the oxidant generation At the end of the lathering timer default 20 seconds the tap will automatically run for 3 seconds This 3 second run time has two purposes a Can be used as a timer for users to ensur...

Page 3: ...f water flow rate the water conductivity TDS and water composition In other words residual ozone is a function of the water composition such as hardness alkalinity PH iron manganese colour odour bacteria etc and the flow rate or length of time the generator is running with no flow rate during the lather time or during trap purge disinfection cycle The mix of produced ozone and other mixed radicals...

Page 4: ...é du lavage des mains Les autres caractéristiques comprennent un cycle de post lavage de 3 secondes assurant l évacuation des résidus de savon et des bactéries et un cycle de purge quotidien pour empêcher l eau de stagner dans les tuyauteries et ainsi assurer une désinfection continue de l évacuation Ce procédé permet de désinfecter tout siphon en P standard Le produit Ozo flo a été conçu exclusiv...

Page 5: ...lage en fixant la jupe au mur Directives pour HWF05 HWF23 HWF43 a continué Test Une fois le robinet activé l eau doit s écouler et l anneau bleu sur ce robinet s allume Lorsque vous retirez vos mains le robinet arrête l écoulement de l eau et fait démarrer la minuterie de lavage Pendant ce temps l intensité de l anneau à DEL varie par impulsions Pendant cette opération contrôlée par minuterie la c...

Page 6: ... la teneur en MDT ou matières dissoutes totales et de la composition de l eau Autrement dit l ozone résiduel est fonction des caractéristiques de l eau dureté alcalinité pH fer manganèse couleur odeur bactéries etc et du débit d eau ou de la durée de fonctionnement du générateur à un débit nul pendant le lavage ou durant le cycle de nettoyage et désin fection du siphon Le mélange de l ozone produi...

Page 7: ...t Ozo flo GARANTIE Le bec du robinet automatique les câbles et le bloc d alimentation électrique PSU sont garantis 2 ans à partir de la date d achat contre les défauts de matériaux et d assemblage L électrovanne est garantie pendant 12 mois sous réserve de la composition de l eau on prévoit cependant que le mécanisme de cette électrovanne fonctionne efficacement durant plusieurs années ...

Page 8: ...outlet of the faucet Using a wrench unscrew the outlet and activate the faucet This will be full line pressure If flow rate without the outlet is still low check for adequate flow rate prior to the mixing valve d Blockages can occur in inlet screens of the mixing valve as well as the inlet of the solenoid valve AC17 104 6V in the wall housing Too much water flow a Water flow is controlled by the o...

Page 9: ...t in front of the sensor If so remove and test b Even with debris in front of the sensor the water flow should cease after 1 minute as part of the anti vandal features If water continues to run cycle the power on and off by unplugging the transformer When the faucet is first plugged in the system will send a pulse to the plug in transformer to close c If the water continues to run try activating t...

Page 10: ...075 106737 ozo bsplt Ozo flo ABS Base 0075 106775 ozo ss bsplt Ozo flo Base Plate 0075 106882 ozo cap Ozo flo Cap 0075 106752 AT00 190 Ozone Phase 3 Interface Control Unit 0075 107115 0075 106409 Decorative Retention Nut 0075 106409 screws not included 0075 106409 Decorative Retention Nut 0075 106409 ...

Page 11: ...2 11 19 Appendix OZO FLO Troubleshooting APPENDIX OZO FLO models HWF05 HWF23 HWF43 0075 106745 Ozone Generator Assembly 0075 106745 OZO CAP Ozo flo Cap 0075 106752 ...

Page 12: ...el 1 855 446 5663 CANADA Tel 1 855 526 0503 USA www franke commercial com commercial info ca franke com Canada commercial info us franke com USA 11 19 Appendix OZO FLO Troubleshooting SLNA1 Solenoid Connection Kit 0075 106053 AC17 104 Anti Microbial Valve c w Spade 0075 105993 ...

Reviews: