background image

Franke Kindred Canada Limited

1000 Franke Kindred Road

Midland, ON  L4R 4K9

Tel  

1.855.446.5663

Fax  

1-866-227-3050

www.franke-commercial.com

02/22 | OZOZMI-02-2022 | 

OZO-FLO FAUCET installation

 

 

         The automatic faucet spout, cables and Power Supply Unit (PSU) is guaranteed for 2 years from purchase against defective ma-

terial and assembly. The solenoid valve is guaranteed for 12 months, subject to water condition, however it is expected that the valve mecha-

nism will operate efficiently for many years. 

WARRANTY

the valve is not triggering and power and connections are validated, 

replace solenoid valve with part number AC17-104.

Water triggers but does not stop -

 Ensure that the range setting 

for distance is properly set for the faucet. Use handheld programmer 

part number AC01-005 (sold separately) to adjust range or contact 

your local rep.

LED blinking once per second

 - This indicates that the output of 

the ozone generator is low. Verify that the ozone chamber is filled 

with water. When activated you should see bubbles being generated. 

Verify that the ozone generator cable is connected (blue banded 

cable). Otherwise verify your local water TDS. Ozo-flo is recommend-

ed for water above TDS of 75.

LED blinking 2x per second

 - This indicates the ozone generator 

is drawing too much current and the system has shut off power for 

protection. Inspect ozone generator for a short between the mesh 

plates. Verify your local water TDS is not above 400. If you have high 

TDS contact our customer service and we can assist with proper 

generator sizing.

Tap Dripping

 - When the ozone generator is charging the canister, 

traces of ozonated water will be released from the tap. This is normal 

operation and will only occurr when the LED is pulsing in intensity 

(for approximately 90 seconds). If the dripping is constant, the so-

lenoid valve may have debris on its internal seal/seat. The solenoid 

may be disassembled for cleaning or you may order a replacement 

(part number AC17-104)

OZONE GENERATOR TECHNICAL INFORMATION

The ozone generator within Ozo-flo not only generates ozone but 

also other powerful oxidants such as oxygen atoms, (O2 ), hydrogen 

peroxide and hydroxyl radicals which all work together to destroy 

harmful bacteria and viruses.

The residual ozone (O3 ) & mixed oxidants produced by the system is 

a function of water flow rate, the water conductivity (TDS) and water 

composition. In other words, residual ozone is a function of the water 

composition (such as hardness, alkalinity, PH, iron, manganese, 

colour, odour, bacteria, etc.) and the flow rate (or length of time the 

generator is running with no flow rate during the lather time or during 

trap purge disinfection cycle). The mix of produced ozone and other 

mixed radicals is also dependent on local water conditions. 

For optimum performance, we recommend installation in areas with 

conductivity between 75-350TDS. If below 75TDS, the ozone genera-

tor will still function down to as low as TDS of 50; however, oxidant 

output may be reduced to under 0.5ppm. In areas above 350TDS, 

we may recommend a smaller ozone generator as to not max out the 

power supply. TDS can be measured using a small TDS reader, your 

local water or pool supply store or by sending in a sample of 250ml 

minimum to our customer service. 

We recommend the DPD test to measure ozone generator output as 

it also takes into consideration the additional mixed oxidant poten-

tial. Tests such as ORP and Indigo may not give valid readings due 

to hydrogen interference, temperature, water composition and PH. 

Subtract the reading obtained from straight tap water to remove any 

reading from chlorine.

The default operation of the ozone generator is to run a charge cycle 

after every use. Target canister charge is 2.0ppm of mixed oxidants. 

During this charge cycle, you will see the LED pulse in intensity (this can 

be adjusted or turned off with the handheld programmer AC01-005)

Typical approximate output is as follows:

@150 TDS =17minutes  

@200 TDS =12 minutes 

 

@250 TDS =7 minutes  

@300 TDS = 4 minutes 

@350 TDS =3 minutes

During a hand wash cycle, when the initial signal is received to wash 

hands, the user typically wets their hands and then commences 

lathering. While they pull away their hands to lather, the water flow 

will stop but we keep the ozone generator running for 20 seconds to 

build up concentration in the chamber to be available for the rinse 

cycle. Alternatively, after 20 seconds of last use the water flow will 

automatically come on for an additional 3 seconds. The intention is 

that 20 seconds after last use, the sink will dispense a small amount 

of water for a post-rinse clean of the sink and trap to remove any 

remaining soap residue.

Note: 

 Water softeners will increase TDS and are recommended 

if your conductivity is low; however, reverse osmosis or de-ionized 

water is not compatible with Ozo-flo.

Summary of Contents for HWF05

Page 1: ... drain and trap free of CPOs and other pathogens This also improves the efficiency of hand washing Other control features include a post wash cycle of 3 seconds which ensures all soap residue and bacteria has been washed down the sink and a daily purge cycle to prevent stagnant water in the lines and ensure continuous waste disinfection Any standard P trap will be disinfected with this process Ozo...

Page 2: ...eration the concentration of ozone and other mixed oxidants are building in the chamber The faucet will slowly drip from the spout This is normal as the volume in the chamber is increasing due to the oxidant generation At the end of the lathering timer default 20 seconds the tap will automatically run for 3 seconds This 3 second run time has two purposes a Can be used as a timer for users to ensur...

Page 3: ...f water flow rate the water conductivity TDS and water composition In other words residual ozone is a function of the water composition such as hardness alkalinity PH iron manganese colour odour bacteria etc and the flow rate or length of time the generator is running with no flow rate during the lather time or during trap purge disinfection cycle The mix of produced ozone and other mixed radicals...

Page 4: ...é du lavage des mains Les autres caractéristiques comprennent un cycle de post lavage de 3 secondes assurant l évacuation des résidus de savon et des bactéries et un cycle de purge quotidien pour empêcher l eau de stagner dans les tuyauteries et ainsi assurer une désinfection continue de l évacuation Ce procédé permet de désinfecter tout siphon en P standard Le produit Ozo flo a été conçu exclusiv...

Page 5: ...lage en fixant la jupe au mur Directives pour HWF05 HWF23 HWF43 a continué Test Une fois le robinet activé l eau doit s écouler et l anneau bleu sur ce robinet s allume Lorsque vous retirez vos mains le robinet arrête l écoulement de l eau et fait démarrer la minuterie de lavage Pendant ce temps l intensité de l anneau à DEL varie par impulsions Pendant cette opération contrôlée par minuterie la c...

Page 6: ... la teneur en MDT ou matières dissoutes totales et de la composition de l eau Autrement dit l ozone résiduel est fonction des caractéristiques de l eau dureté alcalinité pH fer manganèse couleur odeur bactéries etc et du débit d eau ou de la durée de fonctionnement du générateur à un débit nul pendant le lavage ou durant le cycle de nettoyage et désin fection du siphon Le mélange de l ozone produi...

Page 7: ...t Ozo flo GARANTIE Le bec du robinet automatique les câbles et le bloc d alimentation électrique PSU sont garantis 2 ans à partir de la date d achat contre les défauts de matériaux et d assemblage L électrovanne est garantie pendant 12 mois sous réserve de la composition de l eau on prévoit cependant que le mécanisme de cette électrovanne fonctionne efficacement durant plusieurs années ...

Page 8: ...outlet of the faucet Using a wrench unscrew the outlet and activate the faucet This will be full line pressure If flow rate without the outlet is still low check for adequate flow rate prior to the mixing valve d Blockages can occur in inlet screens of the mixing valve as well as the inlet of the solenoid valve AC17 104 6V in the wall housing Too much water flow a Water flow is controlled by the o...

Page 9: ...t in front of the sensor If so remove and test b Even with debris in front of the sensor the water flow should cease after 1 minute as part of the anti vandal features If water continues to run cycle the power on and off by unplugging the transformer When the faucet is first plugged in the system will send a pulse to the plug in transformer to close c If the water continues to run try activating t...

Page 10: ...075 106737 ozo bsplt Ozo flo ABS Base 0075 106775 ozo ss bsplt Ozo flo Base Plate 0075 106882 ozo cap Ozo flo Cap 0075 106752 AT00 190 Ozone Phase 3 Interface Control Unit 0075 107115 0075 106409 Decorative Retention Nut 0075 106409 screws not included 0075 106409 Decorative Retention Nut 0075 106409 ...

Page 11: ...2 11 19 Appendix OZO FLO Troubleshooting APPENDIX OZO FLO models HWF05 HWF23 HWF43 0075 106745 Ozone Generator Assembly 0075 106745 OZO CAP Ozo flo Cap 0075 106752 ...

Page 12: ...el 1 855 446 5663 CANADA Tel 1 855 526 0503 USA www franke commercial com commercial info ca franke com Canada commercial info us franke com USA 11 19 Appendix OZO FLO Troubleshooting SLNA1 Solenoid Connection Kit 0075 106053 AC17 104 Anti Microbial Valve c w Spade 0075 105993 ...

Reviews: