31
INSTALLATION INSTRUCTIONS
FOR FIG301S1 N/L, FIG301B1 N/L, FIG604S1 N/L, FIG604B1 N/L, FIG903S1 N/L, FIG903B1 N/L,
FIG906S1 N/L, FIG906B1 N/L, FIG905B1 N/L, FIXG905B1 N/L, FIXG903B1 N/L
INSTALLATION INSTRUCTIONS - THIS APPLIANCE MUST BE INSTALLED BY AN AUTHORISED PERSON.
_______________________________________________________________________________________________________________________
Your Franke cook top must be installed in accordance with the installation requirements of the local gas and electrical
authorities and the appropriate installation requirements of ASNZ5601, wiring regulations of ASNZS3000 and any other
building requirements.
The electrical connection for the 240V AC supply is by plug to a switched GPO. Franke models with induction must be wired to
a 15 Amp switched GPO socket. Do not remove plug and fix wire.
A 60 mm gap is to be provided around base of unit and models noted as having base surface temperatures above 95
◦
C must
have a removable barrier fitted below to prevent accidental contact.
The appliance is not intended to be operated by means of an external timer or separate remote control system.
1.
Determine the position where your Franke cooktop is to be installed ensuring no structural members interfere with the
space requirements.
Clearances:
For gas cooktops with a FullSpectrum burner (due to the high heat output), ensure that there is at least 700
mm clearance between the benchtop and the rangehood above, or in cases without a rangehood, at least 800 mm between
the benchtop and any overhead downward facing combustible surface located above the cooktop. For induction cooktops,
please ensure a minimum clearance of 600 mm above the benchtop (for both rangehood and any overhead downward facing
combustible surface located above the cooktop).
Ensure that there is a minimum gap of a least 100 mm from the outer edge of the installed cooktop to any nearby combustible
surface.
2.
Ensure that both gas and electrical outlets are accessible paying particular attention to the routing of the gas supply line.
Ensure that there will be a minimum of 60 mm clearance around the underside of the installed cooktop for ventilation.
3.
Mark out the required opening in your bench top using the dimensions shown. Ensure that there is a minimum 630 mm
clearance above the cooktop. Once the opening has been cut out install the appliance and fix into position using the
supplied clamping brackets as shown.
NOTE: DO NOT OVER TIGHTEN BRACKETS AS THIS MAY DISTORT THE APPLIANCE
Respective locations of gas inlet and power supply
405mm
352mm
65mm
378mm
320mm
30m
m
55mm
660mm
505mm
A
A+20mm
60mm
560mm
470mm
330mm
65mm