Sensors situated inside the top constantly measures the temperature of the generator`s electronic circuits. In the event
of these circuits overheating the system reacts as follows:
•
When the first temperature is exceeded the system automatically switches off the booster. If activated, this initiates a
flashing `P` on the respective display showing that the booster cannot be responded to at the moment. When exceeding
a second medium temperature limit, the induction system reduces the power outlet to avoid any temperature increase.
When the temperature of the cooking zone exceeds a third temperature limit, the cooking zone is cut off automatically
from the induction system. The corresponding display indicates a flashing error code E2, possibly alternating with `H`.
The overheating of the circuits definitely indicates an anomaly, and means that the cook top has not been installed
properly or the openings for air circulation are not large enough.
ERROR TABLE
_______________________________________________________________________________________________________________________
CODE
DESCRIPTION
POSSIBLE CAUSE
ACTION
ER 22
Key evaluation defective,
control unit cuts off after
3.5-7.5 sec
Short circuit or
discontinuation in the range of
the key evaluation
Contact Franke Service
03 9700 9100
ER 47
Communication error
between knob control and
induction
None or faulty
communication. Ensure that
connection cable is plugged
on correctly.
Contact Franke Service
03 9700 9100
ER 31
Configuration data incorrect
Configuration of induction
necessary
Contact Franke Service
03 9700 9100
U400
Secondary voltage of the
power unit to high
(Primary>300v) Control unit
cuts off after 1 sec releasing
a permanent tone.
Control unit is wrongly
connected
Contact Franke Service
03 9700 9100
E2
Overheating of the induction
coils
Cooling down necessary
Contact Franke Service
03 9700 9100
E5
Error on filter board
Exchange filter board
Contact Franke Service
03 9700 9100
E6
Error on Power board
Exchange power unit
Contact Franke Service
03 9700 9100
ER 20
Flash failure
Exchange temperature sensor
Contact Franke Service
03 9700 9100
E9
Coil temperature sensor
defective
Exchange temperature sensor
Contact Franke Service