17
MOUNTING THE BUILT-IN COOKTOP
Caution!
• To avoid any possible hazard, the appliance may be installed by qualified personnel only.
• Panels and furniture lining of the kitchen cabinet receiving the hob must be treated with temperature resistant
adhesives (100°C), otherwise they might be discoloured or deformed because of inadequate temperature
resistance.
• The cooking hob is intended for building into the worktop above the kitchen element of 600mm width or more.
• After the installation of built-in hob make sure that there is free access to the two fixing elements in front.
• Suspended kitchen elements above the cooktop must be installed at such distance to provide enough room for
comfortable working process.
• The distance between the worktop and the hood must be at least such as indicated in the instructions for
installation of the kitchen hood, but in no case it may be less than 700mm.
• The use of hard wood decorative borders around the worktop behind the appliance is allowed, in case the
minimum distance remains as indicated on the installation illustrations.
• Minimum distance between the built-in cooktop and rear wall is indicated at the illustration for the installation of
the built-in cooktop.
Built-in hob opening
dimensions
TP 513 V11
TP 614 V11
FHC 6004 4C T XS V11
TP 613 V11
TX 604 V11
TX 302 V11
A
600mm 580mm 288mm
B
435mm 510mm 510mm
C
580mm 560mm 270mm
D
415mm 490mm 490mm
E
40mm 40mm 40mm
F
10mm 10mm 10mm
G
50mm 50mm 50mm
H
5mm 5mm 5mm