Chapter 1
Ready, set up, go
16
WARNING: In order to prevent accidental tipping of the appliance, for example a child climbing onto
the open oven door, the stabilising means must be installed. Ensure the chains are correctly anchored
to prevent the appliance from tilting forward and to prevent strain on the hose when the cooker is
pulled forward.
MAKE SURE THE ANTI-TILTING CHAINS ARE TAUGHT WHEN ANCHORED TO PREVENT THE
APPLIANCE TILTING.
CONVERSION TO DIFFERENT TYPES OF GAS
Before performing any maintenance operation, disconnect the appliance from the gas supply and
electricity network.
REPLACING THE NOZZLES TO OPERATE WITH ANOTHER TYPE OF GAS
When converting to ULPG remove the NG gas regulator (if fitted) and fit ULPG test point adaptor.
If converting to Natural Gas, fit gas regulator
Follow the instructions below to change the burner nozzles on the work surface:
1) Pull out the plug from the electric outlet to avoid any type of electric contact.
2) Remove the grids from the work surface (Fig. 11).
3) Remove the burners (Fig. 11).
4) Unscrew the nozzles using a 7 mm spanner, and replace them (Fig.12) with those needed for the
new type of gas according to what is indicated in the Energy Consumption Table.
Fig 010
Fig. 11 (representation only)
Fig.12