Franke Kaffeemaschinen AG
Configuration | 10
User manual SB1200 FM CM
65
Menu item 1.10 Milk system
Parameter
Value range
Remarks
Version/configuration
– No milk system
– MS EC
– FM EC
– FM CM
– FoamMaster Twin (FM
CM and FM EC)
– Autosteam
Display of the milk system that was configured under
Menu item 0.1 Machine
Milk type 1
Display of milk type 1 that was configured in Menu item
0.2 Configuration
Milk type 2
Display of milk type 2 that was configured in Menu item
0.2 Configuration
Monitoring
– W: Inner wall
– L: Milk line
– W/L: Inner wall and
milk line
– Without
–
W
: Inner wall: The fill level of the milk is monitored
via a capacitive sensor on the inner side wall of the
cooling unit
– The following error messages appear if the mini-
mum level is not reached:
Milk 1: E620, after the time set under empty
message has expired E619
Milk 2: E622, after the time set under empty
message has expired E621
– When milk has been refilled, the milk system will
be prepared automatically when a milk product is
dispensed
–
L
: Milk line: The fill level of the milk is monitored by a
sensor in the milk line.
– If no milk is flowing through the milk line, the er-
ror messages 617 (milk 1) and 618 (milk 2) ap-
pear. The dispensing of a milk product is can-
celed immediately and the products are blocked
– If the milk runs out while a milk product is being dis-
pensed, the error message
Product cancellation due
to insufficient milk 1 [milk type]
appears. The user
then has the opportunity to add milk via a guided
process, prepare the milk system, and repeat the
canceled product output. If the process is ended by
the operator, the money that has been paid into the
machine is forfeited when the accounting system is
switched on
–
Without
: No continuous level sensor for the milk
– Default FM:
Inner wall
– Default MS:
Milk line
Displaying the milk temper-
ature
– Yes
– No