Franke Kaffeemaschinen AG
Filling and emptying | 7
User manual SB1200 FM CM
47
2. Remove the grounds container.
3. Empty, clean, and dry the grounds container.
4. Insert the grounds container and close the door.
7.10 Emptying the cooling unit
NOTICE
Spoiled milk and ready-to-drink beverages
Insufficient cooling or hygiene can cause milk and ready-to-drink beverages to spoil.
a)
Only use precooled milk and precooled ready-to-drink beverages (2,0-5,0 °C).
b)
Only clean containers should be filled with milk and ready-to-drink beverages.
c)
Only store milk and ready-to-drink beverages in the cooling unit when the cooling unit is in operation. When the
cooling unit is not in operation, e.g. overnight, store milk and ready-to-drink beverages in a refrigerator.
d)
Clean the machine and cooling unit once a day.
e)
Only touch the suction hose, the inside of the container, and the container lid after sanitizing your hands, or
wear single use gloves.
f)
Place the container lid with the suction hose on a clean surface only.
7.10.1 SU12/UT12 FM CM 2OM cooling unit
1. Open the cooling unit door.