EN
8
8
Air outlet – Recirculation Version
• Insert the Connector extensions
14.1
into the side of the
Connector
15
.
• Insert the Connector
15
into the Support bracket
7.3
and
fix it with the screws.
• Fasten the Support bracket
7.3
, fixing it to the upper
part with the Screws.
• Make sure that the Connector extensions outlet
14.1
is
in correspondence with the Chimney openings both
horizontally and vertically.
• Join the Connector
15
to the Hood canopy outlet using a
rigid or flexible pipe ø¸150 mm, selection of which is at
the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has
been fitted.
7.3
7.3
12c
12e
15
14.1
Flue assembly - Mounting the hood body
• Position the upper chimney section and fix the upper
part to the frame using the 2 screws
12c
(2,9 x 6,5) pro-
vided.
• Similarly, position the lower chimney section and fix
the lower part to the frame using the 2 screws
12c
(2,9 x
6,5) provided.
Before fixing the hood canopy to the frame:
• Screw the 2 screws
12f
half way into the holes provided
in the sides of the bottom of the frame.
• Remove the grease filters from the hood canopy.
• Remove any activated charcoal filters.
• Lift the hood canopy and engage the screws
12f
in the
slots (
A
) as far as they will go.
• Working from below, fix the hood canopy to the frame
(
B
), using the 4 screws
12q
and 4 washers
22
provided,
then tighten all the screws securely.