FAULTS AND REMEDIES
EN
Warning! The operations should be carried out by a qualified professional.
8.1 DIAGNOSIS AND OPERATING ANOMALIES
This section includes the typical anomalies that could occur.
Many of these problems are not caused by the cooler, but they could be brought about by the electricity supply or by an incorrect use of the water cooler.
In the ANOMALY column, the problems report by the customer are listed.
In the POSSIBLE CAUSES column, the “probable reasons” behind the problem are listed.
In the INTERVENTION column, the corresponding corrective action is listed.
8.2 COOLING SYSTEM
anoMaly
PossiBle cause
interVention
The compressor will not start.
Power failure.
Check that there is voltage in the plug.
Thermostat on the off position, or set to the
minimum.
Adjust the thermostat position.
Faulty thermostat.
Replace the thermostat.
The over-load protection of the compressor is
faulty.
Replace it.
The starting relay is faulty.
Replace it.
The starting capacitor is faulty.
Replace it.
The compressor is faulty
Replace it.
The water is could but the appliance is operat-
ing excessively or non-stop.
Little ventilation.
Place the appliance away from the wall.
The condenser is dirty or covered.
Clean the condenser or free it of its obstacles.
The thermostat is on maximum could position.
Adjust it.
The room temperature is heigher than 32°C.
It is normal that the appliance works at a con-
tinuously high room temperature.
The compressor works continuously, but the
water is not cold.
Gas leak from the cooling system.
Contact a specialised technician (Refrigerationist).
The compressor is faulty.
Replace the compressor.
COOLING SYSTEM
Too much noise coming from the appliance, but
it is working normally.
The machine is not levelled.
Level the appliance using the adjustable feet.
A few pipes are touching some parts inside the
appliance, thus causing it to vibrate.
Adjust the position of the pipes, making sure
they do not touch any other parts.
Could water comes out slowly or not all.
Low pressure of the inlet water.
Take steps to increase the pressure (autoclave).
Faulty solenoid valve.
Replace it.
Clogged water filter.
Replace it.
The temperature adjuster is faulty and causes
complete freezing of the ice compartment.
Make the ice melt.
Replace the temperature adjuster.