Selecting the temperature
Sink mixer
with mixing lever
13.3
Set the mixing lever (a) in the desired position.
14. Setting the Range
The signal range can be adjusted with a free program available from Franke.
15. Setting Hygiene Flushing
Hygiene flushing can be adjusted with a free program available from Franke.
16. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and
regulations applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
• Aerators (see
• Filters (see
16.1
Switch the fitting into the cleaning mode via the AQUA 3000 open system software.
or wait
Switch the fitting into the cleaning mode via an external switch on the ECC function
controller.
or wait
Disconnect the cable connection between the fitting and the electric T-junction.
16.2
Properly use suitable cleaning agents that are not harmful to the fittings and rinse
with water after use. High-pressure cleaners must not be used for cleaning.
17. Replacing an Aerator
17.1
Use the special wrench (b; see
) to unscrew and remove the anti-theft
aerator (a).
18. Replacing the Grit Filters
Filter for corner valve
18.1
Close the corner valves (c).
18.2
Trigger the valve.
18.3
Unscrew the connector hoses (a) from the corner valves.
18.4
Replace the grit filters (b).
18.5
Reassemble in the reverse order.