21. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
22. Replacement Parts
Fault
Cause
Remedy
Water does not flow
– Voltage supply interrupted
➯
Restore it
– Water-flow volume regulator closed
➯
Open it
– Grit filters are clogged with dirt
➯
Clean them
– Cleaning mode active
➯
Deactivate it
– Solenoid valve faulty
➯
Replace it
Water flows
continuously
– Solenoid valve faulty
➯
Replace it
Water flow too weak
– Corner valves not fully opened
➯
Open it
– Grit filters are clogged with dirt
➯
Clean them
– Aerator calcified
➯
Replace it
– Solenoid valve faulty
➯
Replace it
– Supply pressure too low
➯
Check it
Water is too hot
– Cold water is turned off
➯
Open it
– Filter in cold-water part is dirty
➯
Replace it
– Non-return valve faulty
➯
Replace it
Water is too cold
– Hot water is turned off
➯
Open it
– Filter in hot-water part is dirty
➯
Replace it
– Non-return valve faulty
➯
Replace it
Designation
Order No.
1 Aerator with
flow rate regulator . . . . . . . . . . 2000101160
2 Solenoid valve cartridge
with grit filter . . . . . . . . . . . . . 2000104456
3 Cleaning clip . . . . . . . . . . . . . . . . 2000105795
4 Maintenance kit comprising:
O-rings
Screws
Grit filters. . . . . . . . . . . . . . . . . 2000104898
5 Mixing lever with screw. . . . . . . . . 2000105821
(only for Order No. 2000101161)
Designation
Order No.
6 Maintenance kit comprising:
Non-return valve
Grit filters . . . . . . . . . . . . . . . . . 2000105106
7 Hose . . . . . . . . . . . . . . . . . . . . . . . 2000109491
Accessories
Order No.
8 Base for installation
on stainless steel washbasin . . . . 2000105834
9 Special spanner for
theft-proof aerator . . . . . . . . . . 2000105960