Scope of Delivery
8.
Dimensions
9.
Installation Example
10. Preparing Electrical Connection
Materials required
To be provided by the customer:
• Conduit for system cabels
• Damp-room junction box (
≥
100 mm ×
≥
100 mm)
Accessories
Order No.
Function controller
with Ethernet connection (60 W)
ECC1 . . . . . . . . . . . . . . . . . . . . . . . . . 2000100368
ECC2 . . . . . . . . . . . . . . . . . . . . . . . . . 2000108123
System cable
blue, 100 m . . . . . . . . . . . . . . . . . . . . 2000104272
blue, 25 m . . . . . . . . . . . . . . . . . . . . . 2000104274
gray, not halogen-free, 100 m . . . . . . 2000100801
gray, not halogen-free, 25 m . . . . . . . 2000100852
Terminating resistor . . . . . . . . . . . . . . . 2000100847
Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (ECC function controller, not included in the scope of delivery,
see accessories) must be set up outside of the wet area, in a separate room.
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
10.1
Install one damp-room junction box (a) for each fitting.
10.2
Lay the system cable (b) through the conduit, and loop it from fitting to fitting.
☞
Let the system cable hang out of the damp-room junction box approx. 50 cm.
Quantity
Description
1
PROTRONIC-C pillar tap with non-return valves and filters
1
Cleaning clip
1
Electric T-junction
1
Fastening set
1
Installation and Operating Instructions