background image

FRANCO srl                                                                                                                  Manual of use and maintenance UCP 

 

1.3 Conventions used in this manual 

 
The Manual is divided into autonomous chapters, each of which is addressed to a specific operator figures 
(installer, operator and maintenance operator), who have the skills needed to operate the machinery safely. 
The chapter order follows the temporal logic of the machine life. 
To facilitate the immediate understanding of the text, terms, abbreviations and pictograms, whose meaning is 
shown below, are used throughout the manual. 
The Instruction Manual consists of a cover, an index and a series of chapters (sections). 
The home page lists the machine and model identification data, the revision of the instruction manual, and 
finally, a picture of the described machine, drawn in order to facilitate the reader to identify the machine and its 
use. 
 

ABBREVIAZIONI 

Ch. 

=  Chapter 

Par. 

=  Paragraph 

P. 

=  Page 

Fig. 

=  Figure 

Tab. 

=  Table 

 

UNITS OF MEASURE 

The units of measure used in this manual are those provided by the International System (SI). 
 

1.4 Instruction manual conservation 

 
The instruction manual must be carefully stored and must follow and match the device in all the cases of change 
of ownership incurred during the life span of the machine itself.  
The manual must be handled with care, with clean hands and placed on clean surfaces. No parts can be 
removed, torn or arbitrarily modified. 
The manual must be stored in a secure environment, protected from moisture and heat, and near the device to 
which it refers. The manufacturer, if requested by the User, may provide additional copies of the 

machine’s 

instruction manual. 
The User can request additional copies of the manual by writing to 

[email protected]

 

UPDATING THE MANUAL 

 
The Manufacturer reserves the right to modify the design or specifications of the machine as part of its policy of 
improving and enabling them to comply  with  the statutory  or other requirements or standards applicable in  any 
territory  in  which its  goods  are sold,  without notifying  the Customer and  without  updating the manuals given to 
the user. Moreover, in case of changes (previously agreed between the Customer and the manufacturer) to the 
machine installed,  which entails a change  in one or  more chapters of  the Instruction manual,  the manufacturer 
will be responsible for sending the modified chapters (including the new revision) to the User. 
The User is responsible, following the directions accompanying the updated documentation, for replacing all the 
copies owned, the old chapters with the new ones, the home page, and the index with the new updated version. 
 
 
 
The manufacturer shall be responsible for the descriptions included in this manual; in case of any inconsistency 
detected in a translated version of the manual (English version), the reader must refer back to the original Italian 
version of the manual and, if needed, contact the sales department, who will make necessary changes. 
 

Summary of Contents for UCP

Page 1: ...TION MANUAL FOR USE AND MAINTENANCE UCP CENTRIFUGAL HUMIDIFIER TRANSLATED VERSION FROM ITALIAN TO E N G L I S H Before installing or running the unit it is mandatory to carefully read and consult this...

Page 2: ...and handling 10 1 12 Warranty 11 1 13 Manufacturer s identification data 11 1 14 Declarations 11 1 15 Declaration of incorporation 12 2 INSTALLATION 13 2 1 Before installing 13 2 2 Positioning 13 2 3...

Page 3: ...into water or any other liquid In case of the device becoming wet immediately turn off the electricity by lowering the switch on the electrical panel of your system and disconnect the power before to...

Page 4: ...modified The manual must be stored in a secure environment protected from moisture and heat and near the device to which it refers The manufacturer if requested by the User may provide additional cop...

Page 5: ...iar with the specific applicable rules Have understood the operating procedures defined by the manufacturer of the machine 1 6 Glossary and pictograms In this section we list the uncommon terms includ...

Page 6: ...occurrence of the expected result or endanger the safety of the personnel involved STATE OF THE MACHINE The state of the machine includes the operating mode for example running in automatic mode hold...

Page 7: ...qualified technician able to operate the machine under normal conditions to run it with the hold to run control JOG with disabled protections and enabled to any kind of operation of electrical adjust...

Page 8: ...ON OBLIGATION Pictogram Denomination Hazardous voltage Entanglement Dragging General danger Do not remove safety devices Prohibition of cleaning oiling greasing repairing or adjusting by hand when the...

Page 9: ...the humidification with easy installation and by operating without nozzles it is not subject to clogging caused by impurities and limestone The water pressure required is the same as in the water sup...

Page 10: ...he package to prevent damages to the components of the device Verify the integrity of the machine by controlling that there are no visible damaged parts Do not dispose the packaging elements in the en...

Page 11: ...anco s r l undertakes to replace or repair free of charge those parts which result faulty from the origin The intervention must be made at Franco s r l with transport borne by the user 1 13 Manufactur...

Page 12: ...irective 2006 95 CE Directive 2004 108 CE The relevant technical documentation has been compiled in accordance with the annex VII B of machinery directive All relevant information about the partly com...

Page 13: ...2 2 Positioning The UCP humidifier must be installed either in front of a stirring air fan or as a part of a dynamic ventilation system The UCP humidifier cooler must be installed horizontally hanging...

Page 14: ...below Electrical connections must be performed by specialized experienced and trained technicians in accordance with the current legislation Ensure that the electricity supply specifications correspo...

Page 15: ...g an excessive quantity of water increase the size of the droplets The pump must not operate without water The temperature of the liquid used must not exceed 35 C 3 3 Starting The machine starts autom...

Page 16: ...ping the grip To ease the cleaning it is possible to remove the float s ball and the pump To remove the ball it is necessary to unscrew the plastic arm of the float Fig 4 1 To remove the pump it is ne...

Page 17: ...disk Lever it off using a flat heat screwdriver on the specific groove B With a nut driver pic no 7 remove the M4 screw that fixes the disk to the motor shaft Then remove also the washer C Insert the...

Page 18: ...M4 and the cap The distance between the spinning disk and the fixed disk must be about 4mm If it is not adjust it by adding a spacer or taking a spacer off the motor shaft item 5 on the spare parts li...

Page 19: ...ut the nozzle Place the new nozzle repeating the sequence in the reverse order 4 7 Accessories A full range of accessories matching your UCP is available including electronic humidity controls thermos...

Page 20: ...5 40 15 40 15 40 Electrical supply 1 phase 3 phases neutral 1 phase 3 phases Neutral Degree of protection IP 56 56 56 56 Weight kg 7 5 7 5 7 5 7 5 Electrical characteristics Humidifier s motor Power W...

Page 21: ...witch upstream of the device Protect with a suitable motor overload protection par 5 1 Make sure that all connections are stuck on the box that the box cover is secured and that the screws are tighten...

Page 22: ...CAP 2 F 6001001 1 EXAGONAL HEAD INOX SCREW M4x16 3 F 1801006 1 SPINNING DISK FIXING WASHER 4 F 1801002 1 SPINNING DISK 5 F 1801009 F 1801010 2 SPINNING DISK SPACER 1mm SPINNING DISK SPACER 2mm 6 F 60...

Page 23: ...he pump The circuit of water supply is disconnected Check the water supply pipe and the atomizing control valve The pump is clogged Clean the tank and accurately clean the pump The pump is full of air...

Page 24: ...FRANCO s r l Headquarters and plant Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 Fax 39 0171 612337 www francosrl com info francosrl com For further information requests or suggest...

Reviews: