4 - MAINTENANCE 

 
 
 
 
 
 

 

Before undertaking any maintenance,  

disconnect the device from the electricity and water supply! 

 

Periodically check that the amount of water reaching the slinger is correct, if necessary adjust the flow regulator. 
Keep the disks, the tank and the internal components clean, and prevent dirt accumulation on the lid. 
 

4.1 Cleaning the disk 

Keep the disk clean to avoid the formation of calcareous deposits or accumulation of dirt, which could cause an 
increase in vibration or coarse nebulization. 
To  clean  the  rotating  disk,  simply  use  a  soft  damp  cloth  and  a  non-toxic  and  solvent  free  detergent,  and  be 
careful to rub without excessive pressure. 

Do not use solvents. 

The fixed disk should be cleaned with a small brush with stiff bristles, rub the teeth, being careful not to damage 
them. 
Any eventual limescale can be removed with muriatic acid diluted with water. 
 

4.2 Cleaning the tank 

Periodically clean the water tank.  
To access it, unscrew the two screws on the lid and pull gently, grasping the grip. 
To ease the cleaning, it is possible to remove the float’s ball and the pump.  
To remove the ball it is necessary to unscrew the plastic arm of the float (Fig. 4.1). 
To remove the pump it is necessary to operate while holding with a no. 13 spanner the stop ring that blocks the 
pump and pull gently the pump up to complete removal. 
Once all these operations have been completed, it  is possible to clean the interior of the tank with a cloth or a 
sponge, rubbing gently on the walls. 

Do not use solvents

It is necessary to periodically check the functioning and the cleanliness of the pump and the float. 
Each 2-3 months clean the internal parts of the pump with warm water. 
 

 

 

  Fig. 4.1 

 

 

 

 

 

  Fig.4.3 

 

4.3 Changing the pump 

Remove the two co

ver screws using a cross or “Phillips” screwdriver. Remove the lid by pulling it, grabbing the 

grip  between  thumb  and  forefinger.  Unscrew  the  plastic  arm  of the  float  as  shown  in  Fig.  4.1.  Operate  holding 
the  stop  ring  that  blocks  he  pump  with  a  no.  13  spanner  and  pull  the  pump  gently  up  to  complete  removal. 
Remove  the  nylon  pawl  from  the  pump  supply  and  fit  it  onto  the  new  pump.  Repeat  the  sequence  backward, 
being careful to reposition the float so that the water level inside the tank covers the pump completely. 

 

 

Summary of Contents for UCP

Page 1: ...TION MANUAL FOR USE AND MAINTENANCE UCP CENTRIFUGAL HUMIDIFIER TRANSLATED VERSION FROM ITALIAN TO E N G L I S H Before installing or running the unit it is mandatory to carefully read and consult this...

Page 2: ...and handling 10 1 12 Warranty 11 1 13 Manufacturer s identification data 11 1 14 Declarations 11 1 15 Declaration of incorporation 12 2 INSTALLATION 13 2 1 Before installing 13 2 2 Positioning 13 2 3...

Page 3: ...into water or any other liquid In case of the device becoming wet immediately turn off the electricity by lowering the switch on the electrical panel of your system and disconnect the power before to...

Page 4: ...modified The manual must be stored in a secure environment protected from moisture and heat and near the device to which it refers The manufacturer if requested by the User may provide additional cop...

Page 5: ...iar with the specific applicable rules Have understood the operating procedures defined by the manufacturer of the machine 1 6 Glossary and pictograms In this section we list the uncommon terms includ...

Page 6: ...occurrence of the expected result or endanger the safety of the personnel involved STATE OF THE MACHINE The state of the machine includes the operating mode for example running in automatic mode hold...

Page 7: ...qualified technician able to operate the machine under normal conditions to run it with the hold to run control JOG with disabled protections and enabled to any kind of operation of electrical adjust...

Page 8: ...ON OBLIGATION Pictogram Denomination Hazardous voltage Entanglement Dragging General danger Do not remove safety devices Prohibition of cleaning oiling greasing repairing or adjusting by hand when the...

Page 9: ...the humidification with easy installation and by operating without nozzles it is not subject to clogging caused by impurities and limestone The water pressure required is the same as in the water sup...

Page 10: ...he package to prevent damages to the components of the device Verify the integrity of the machine by controlling that there are no visible damaged parts Do not dispose the packaging elements in the en...

Page 11: ...anco s r l undertakes to replace or repair free of charge those parts which result faulty from the origin The intervention must be made at Franco s r l with transport borne by the user 1 13 Manufactur...

Page 12: ...irective 2006 95 CE Directive 2004 108 CE The relevant technical documentation has been compiled in accordance with the annex VII B of machinery directive All relevant information about the partly com...

Page 13: ...2 2 Positioning The UCP humidifier must be installed either in front of a stirring air fan or as a part of a dynamic ventilation system The UCP humidifier cooler must be installed horizontally hanging...

Page 14: ...below Electrical connections must be performed by specialized experienced and trained technicians in accordance with the current legislation Ensure that the electricity supply specifications correspo...

Page 15: ...g an excessive quantity of water increase the size of the droplets The pump must not operate without water The temperature of the liquid used must not exceed 35 C 3 3 Starting The machine starts autom...

Page 16: ...ping the grip To ease the cleaning it is possible to remove the float s ball and the pump To remove the ball it is necessary to unscrew the plastic arm of the float Fig 4 1 To remove the pump it is ne...

Page 17: ...disk Lever it off using a flat heat screwdriver on the specific groove B With a nut driver pic no 7 remove the M4 screw that fixes the disk to the motor shaft Then remove also the washer C Insert the...

Page 18: ...M4 and the cap The distance between the spinning disk and the fixed disk must be about 4mm If it is not adjust it by adding a spacer or taking a spacer off the motor shaft item 5 on the spare parts li...

Page 19: ...ut the nozzle Place the new nozzle repeating the sequence in the reverse order 4 7 Accessories A full range of accessories matching your UCP is available including electronic humidity controls thermos...

Page 20: ...5 40 15 40 15 40 Electrical supply 1 phase 3 phases neutral 1 phase 3 phases Neutral Degree of protection IP 56 56 56 56 Weight kg 7 5 7 5 7 5 7 5 Electrical characteristics Humidifier s motor Power W...

Page 21: ...witch upstream of the device Protect with a suitable motor overload protection par 5 1 Make sure that all connections are stuck on the box that the box cover is secured and that the screws are tighten...

Page 22: ...CAP 2 F 6001001 1 EXAGONAL HEAD INOX SCREW M4x16 3 F 1801006 1 SPINNING DISK FIXING WASHER 4 F 1801002 1 SPINNING DISK 5 F 1801009 F 1801010 2 SPINNING DISK SPACER 1mm SPINNING DISK SPACER 2mm 6 F 60...

Page 23: ...he pump The circuit of water supply is disconnected Check the water supply pipe and the atomizing control valve The pump is clogged Clean the tank and accurately clean the pump The pump is full of air...

Page 24: ...FRANCO s r l Headquarters and plant Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 Fax 39 0171 612337 www francosrl com info francosrl com For further information requests or suggest...

Reviews: