background image

Description of the appliance

Installation instructions

Operating instructions

Spare parts

Warranty certificate

Document n° 1274-1 ~ 03/10/2008

SAVOY MK2

Multifuel stove

Model : 134 08 09

Output (wood) : 8 kW

Output (coal) : 7 kW

Technical manual

to be saved

by the user

for future reference

STAUB FONDERIE

SARL with the capital of 6 359 540 €

Head Office Address

2, rue Saint Gilles

68230 TURCKHEIM

RCS Colmar

SIREN 444 881 953

Address

Administration and manufacturing

BP 73

59660 MERVILLE (FRANCE)

Telephone : 00 333 28 43 43 00

Fax : 00 333 28 43 43 99

Subject to modifications.

EN

FR

NL

ES

IT

PT

PL

CZ

Summary of Contents for SAVOY MK2 134 08 09

Page 1: ...Output wood 8 kW Output coal 7 kW Technical manual to be saved by the user for future reference STAUB FONDERIE SARL with the capital of 6 359 540 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM...

Page 2: ...e shooting p 9 Spare parts p 10 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality of its appliances and is committed to meet its customers needs FRANCO BELGE which can...

Page 3: ...12 Nominal heat output kW 7 2 Efficiency 71 9 Co 13 O2 0 13 1 3 Appliance description Wood stove in conformity with DIN EN 13240 2005 10 Intermittent burning heating appliance Detachable flue spigot f...

Page 4: ...tible material as per the Building regulations Otherwise it must necessary to install a non combustible protection There must be a clearance of at least 150 mm at each side of the appliance and at the...

Page 5: ...diameter of 139 mm The stove is set from the factory with a top outlet 2 5 Top flue outlet Figure 3 First remove the flue baffle A The stove is set from the factory with a top outlet Do not remove the...

Page 6: ...ss for cleaning The spigot should be connected to a minimum of 125 mm flue system and in that case the appliance is capable of burning untreated wood and recommended solid fuels 2 8 Pre utilisation ch...

Page 7: ...not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash ma...

Page 8: ...pliance is cold Remove the ash drawer using the tool provided Empty the ashes carefully with regard to the live embers 3 5 Maintenance of the Chimney Very important In order to avoid any incident chim...

Page 9: ...mall wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Ro...

Page 10: ...ic glass 402 x 322 01 17 189103 Screw 27x8x6 02 18 189104 Screw 6x22 02 19 189825 Screw M5x6 01 20 205362 Back panel 01 21 222581 Flue baffle 01 22 236138 Reducing plate 01 23 237406 Reducing plate 01...

Page 11: ...3 2 1 4 1 4 3 8 4 5 2 1 2 0 3 4 6 7 3 3 4 0 8 4 6 4 1 4 1 3 4 2 1 3 3 9 2 7 4 4 2 3 1 2 3 6 1 7 2 4 2 2 5 3 7 1 4 3 2 5 1 0 1 6 9 1 5 1 8 1 0 2 5 1 0 2 5 2 5 1 0 1 9 3 1 4 2 1 4 3 5 3 0 1 7 1 8 2 9 2...

Page 12: ...he exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or...