3.9. Trouble shooting

Situation

Probable causes

-

Corrective action

Fire difficult to start. Fire goes
out.

Wood green… or too damp

-

Use hard wood logs, which have been cut for at least
two years and stored, under a ventilated shelter.

Logs are too big.

-

To light the fire, use small, very dry twigs. To maintain
the fire, use split logs.

Poor quality wood.

-

Use hardwood that have a higher calorific value per cu
metre (Yoke-elm, oak, ash, maple, birch, elm, beech,
etc.)

Not enough primary air

-

Open air control.

-

Open the outside fresh air inlet grid.

Insufficient draught.

-

Open temporarily the flue damper control.

-

Check that the flue is not obstructed, sweep it if
necessary,

-

Seek advice from a chimney specialist.

Fire burns too quickly.

Too much draught.

-

Partially close the air control.

Excessive draught.

-

Check that the chimney-flap does not remain opened.

-

Install a draught stabiliser to the connector pipe.

Poor quality wood.

-

Do not continuously burn small wood, sticks, bundles,
carpentry offcuts (plywood, pallets), etc.

Smokes when lighting up.

The flue damper is closed

-

Open the flue damper

Flue duct is cold.

-

Burn paper and kindling wood to increase heat.

Room is in decompression
(negative pressure).

-

In houses equipped with mechanical ventilation, partly
open a window until the fire is well established.

Smokes while burning.

Insufficient draught.

-

Open temporarily the flue damper control.

-

Consult a chimney specialist

-

Check that the flue is not obstructed, sweep it if
necessary,

Down draught.

-

Install an anti-down draught cowl.

Room is in decompression
(negative pressure).

-

In houses equipped with mechanical ventilation, an
outside air intake must be installed in addition to the
chimney itself

Low heat output.

Poor quality wood.

-

Use the recommended fuel.

Poor mixing of the convection air.

-

Check the air flow system (air inlet, piping, air outlet).

-

Check that the next rooms are equiped with ventilation
grids to help out the hot air circulation.

14

Technical manual “1248”

“HEKLA” - ref. 634 07 46 & 634 07 47

Instructions for user

: This sign means that you should

asked for a qualified engineer

to do the work.

Summary of Contents for HEKLA 634 07 46

Page 1: ...i ge Social 2 rue Saint Gilles 68230 TURCKHEIM RCS de Colmar SIREN 444 881 953 Si ge Administratif et usine BP 73 59660 MERVILLE T l phone 03 28 43 43 00 Fax 03 28 43 43 99 Mat riel sujet modification...

Page 2: ...s avant mise en service p 11 Acc s aux ventilateurs p 11 Entretien de la chemin e et ramonage p 11 Instructions pour l utilisateur p 12 Combustible p 12 Allumage p 12 Ventilation de l insert p 13 Cond...

Page 3: ...Volume de chauffe corrig m3 240 240 D pression du foyer l allure maxi Pa 12 12 D pression du foyer l allure mini Pa 6 6 D bit massique des fum es g s 8 20 8 20 Temp rature des fum es C 340 340 Rendem...

Page 4: ...rayonnement des parois du foyer et de l avaloir L air chaud s levant naturellement est restitu soit dans la pi ce au travers de la grille de diffusion de la hotte ou au travers du diffuseur en fa ade...

Page 5: ...hotte dans le cas contraire le renforcer par une chape en b ton pour r partir cette charge Dans tous les cas il est pr f rable de sur lever le foyer pour loigner le plancher du rayonnement tr s import...

Page 6: ...ns 6 Notice de r f rence 1248 HEKLA r f 634 07 46 634 07 47 Instructions pour l installateur 2 0 4 5 2 0 s i H 5 m H Figure 4 D voiement du conduit de fum e D D D D 2 3 4 5 6 7 8 9 1 1 0 9 9 3 0 c m 4...

Page 7: ...mm b bloquer la buse de longueur X 530 sur la collerette en cas de d voiement du conduit utiliser un tuyau flexible c si le sol de l tre est rugueux poser une plaque m tallique pour faciliter la mise...

Page 8: ...46 634 07 47 Instructions pour l installateur Figure 9 R glementations d installation D Distance de s curit 16 cm mini partir de la paroi int rieure du conduit ne pas isoler la partie non combustible...

Page 9: ...t le bandeau 2 10 Raccordements lectriques L installation lectrique doit tre r alis e conform ment la r glementation en vigueur Si vous poss dez le mod le 634 07 46 les raccordements lectriques ne ser...

Page 10: ...ure 6 m Pr voir des bouches de diffusion r glables 2 12 Chicane de fum e Figure 14 La chicane bloqu e sur la grille de foyer au d part de l usine doit tre mise en place l int rieur de la chambre de co...

Page 11: ...uter du mastic r fractaire aux coins de la nervure de la fa ade avant de remonter celle ci 2 15 Entretien de la chemin e et ramonage Tr s important Afin d viter tout incident feu de chemin e etc les o...

Page 12: ...de bois trait traverse de chemin de fer poteau t l graphique chute de contreplaqu ou d agglom r palette etc provoque rapidement l encrassement de l installation suies bistre goudron nuit l environnem...

Page 13: ...rdement et le conduit de fum es Ouvrir la porte vitr e et nettoyer toutes les parois de la chambre de combustion nettoyer la grille de foyer Le nettoyage de la vitre sera r alis e lorsque l appareil e...

Page 14: ...te etc Emanation de fum es l allumage Le clapet de tirage est ferm Ouvrir le clapet en grand Le conduit de fum e est froid R chauffer le conduit en faisant br ler une torche de papier dans le foyer La...

Page 15: ...Notice de r f rence 1248 15 HEKLA r f 634 07 46 634 07 47 Notes Notes...

Page 16: ...mique 9 5 A B 1 08 m 15 181622 Tresse de c ramique 8 A B 2 56 m 16 188513 Ventilateur A 02 17 188814 Verre c ramique 504x315x4 A B 01 18 181632 Joint 6 A B 1 m 19 200174 Dessous A B 01 20 217128 Envel...

Page 17: ...Pi ces d tach es 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 2...

Page 18: ...les fusibles les r sistances lectriques les ventilateurs 2 les pi ces d usure ou en contact avec des temp ratures importantes savoir soles et grilles foy res plaques de fond d flecteurs cendriers pein...

Page 19: ...000 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM RCS Colmar SIREN 444 881 953 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 00 Fax 00 333 28...

Page 20: ...ffle mounting p 11 Access to the fans p 11 Maintenance of the Chimney p 11 Instructions for user p 12 Fuel p 12 Lighting p 12 Air convection principle p 13 Operating procedure p 13 De ashing p 13 Clea...

Page 21: ...x 277 x 250 Ash pan capacity litre 3 3 Weight kg 113 113 Heated volume m3 240 240 Firebox draught at maximum rate Pa 12 12 Firebox draught at minimum rate Pa 6 6 Flue mean gas flow g s 8 20 8 20 Flue...

Page 22: ...ir collected at the bottom of the appliance spreads around the body where it becomes hot with the appliance wall radiation The hot air rising up goes to the room through the grille located in the hood...

Page 23: ...ulation if the floor is combustible In all cases it is better to raise the height of the appliance to protect the floor of the heat radiation and allow fresh air required for the convection bellow the...

Page 24: ...ion pipe and any draught stabiliser must have access for cleaning Foreseen an inspection trap 500 x 350 mm in the hood to allow access to the flue 6 Technical manual 1248 HEKLA ref 634 07 46 634 07 47...

Page 25: ...ction X 530 from the stove to the small collar c If the floor of the hearth is rough place a metal plate to ease the setting of the insert fire in the chimney 634 07 46 only The fans must be plugged o...

Page 26: ...Insulation 40 MM R 0 70 rockwool Internal diameter 200 MM Opening 100 X 100 MM Opening 200 X 500 MM Insulation 30 MM 1 wall R 0 80 Opening 100 X 100 MM Opening 200 X 200 MM of only wall Insulation 60...

Page 27: ...tallation operations are completed fixing assembly etc Complies with Low tension Directive 73 23 CEE under standard NF EN60335 1 Electromagnetic compatibility Diretive 89 336 CEE The fans electrical r...

Page 28: ...is possible to fit two outlets to diffuse air to adjacent rooms In this respect Remove the blanking plates on the casing on top of the appliance fig 13 Secure the 5 mm O D screws Fit the flue collars...

Page 29: ...ting it 2 17 Maintenance of the Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regularly If the appliance is regularly used the chimney sh...

Page 30: ...ternal walls and the flue soot tar etc Recovered wood Railway sleepers telegraph poles offcuts of plywood or chip board pallets etc Burning treated wood quickly clogs the flue ways soot tar etc pollut...

Page 31: ...and the flue pipe Open the door and remove all deposits in the firebox and clean the removable fire grate Cleaning of the glass door can be done with a soft cloth dampened with water and vinegar or po...

Page 32: ...wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up The flue damper is closed Open the flue damper Flue duct is cold Burn paper and kindling wood to increase heat Room i...

Page 33: ...Technical manual 1248 15 UHI 1RWH Note...

Page 34: ...A 02 17 188814 Ceramic glass 504x315x4 A B 01 18 181632 Gasket 6 A B 1 m 19 200174 Base A B 01 20 217128 Shell A B 01 21 217231 Shell top A B 01 22 909818 Flue baffle A B 01 23 224046 Ash pan A B 01...

Page 35: ...UWV 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 0 2 5 9 1 5 1 6...

Page 36: ...or all appliances with the exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2...

Reviews: