2.12. Pre-utilisation check
-
Check that the seals of the smoke-line are in good
condition. Check that the door closes correctly.
Check that the glass is not damaged. Check that
the smoke passages are not obstructed by
packaging or removable parts. Check that all
removable parts are correctly installed.
Note :
if it acts of a ceramics braid, it is consumable
and thus brought to be changed by the user.
2.13. Hot air outlets
In the case of the insert fire being the hearth of a
chimney to be built, it is possible to fit two outlets to
diffuse air to adjacent rooms. In this respect :
-
Remove the blanking plates on the casing on top
of the appliance (fig. 13).
-
Secure the 5 mm O.D. screws
-
Fit the flue collars supplied by rotating them,
-
Use
insulated
flexible pipe dia. 125 mm.
-
Avoid using pipes longer than 6 meters.
Eventually use hot-air vent controls.
2.14. Flue baffle
Figure 14
The baffle plate is laid in the hearth when it leaves
the factory. Install flue baffle (attached on hearth
grate before leaving the plant) inside combustion
chamber.
Technical manual “646”
10
“HEKLA” - ref. 634 07 46 & 634 07 47
Installation instructions
Figure 13 -
Hot air
outlets
Figure 14 - Flue baffle mounting
1
- Mounting
2
- Removing