2.15. Flue baffle mounting
Mounting :
-
Locate the baffle on the four screws inside the heater.
-
Place the 2 stops on the screw heads.
-
Tighten the 2 fixing screws
Removing :
To go up them, proceed in the opposite order.
2.16. Access to the fans
Model
634 07 46
only
Figure 15
-
Remove the baffle plate (fig. 14), the draught restrictor
(voir § 2.7., page 7).
-
Open the door to the hearth
4
and remove the ash box
3
, remove the two screws
1
and the door
4
.
-
Remove the four bolts
2
and the front facing
5
.
Note
: For a good seal, apply refractory mastic to the
corners of the ribs on the front facing before refitting it
2.17. Maintenance of the Chimney
Very important :
In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly. If the appliance is regularly used,
the chimney should be swept several times per year,
together with the stovepipe connection section.
If the chimney catches fire, you must cut off the flue
draught, close the doors and windows, hatches and
keys and call the Fire Brigade without delay.
DO NOT OPEN THE DOOR OF THE APPLIANCE
(OR AIR INLET) UNDER ANY CIRCUMSTANCES
Chimney condition should be checked at least once per
year by a professional engineer.
11
Technical manual “646”
“HEKLA” - ref. 634 07 46 & 634 07 47
Installation instructions
Figure 15 - Access to the fans
1
- 2
washers
2
- 2 screws
3
- Ash pan.
4
- Door.
5
- Front plate
6
- Electric fans