Log Layout
Parts : 1 Ceramic mat, 1 Bag of Ceramic Embers and 4
Logs.
-
Place the ceramic mat, on the top of the burner
ensuring that the holes align.
-
Scatter the bag of Embers over the top of the Mat,
ensurethat the Pilot is not impinged or obstructed,
leave the rear of the mat clear.
-
Place the Large “Branched” log on the rear of the
burner, behind the Embers as shown in the figure.
-
Place the “Chared” log in the centre of the fire, on top
the Embers and the rear log as shown in the figure.
-
Place the two remaining logs either side of the centre
log, on top the Embers and the rear log as shown in the
figure.
These should lay with one end of each log in the front
corners by the log bar, the other end should lay on top
of the rear log by the centre log.
2.10 Commissinoing the Stove
A spillage test MUST be made before the installed
stove is left with the customer.
Carry out the test by first closing all doors and windows
in the room containing the stove.
Ensure that the fire is burning at full rate for a minimum
of 5 minutes.
Using a smoke match, run along the edge of the draught
diverter. The smoke should be drawn into the draught
diverter. The test should be made over the full width of
the draught diverter, and the test may be done from
either left or right.
If most of the smoke is not drawn into the draught
diverter leave for a further 10 minutes and repeat.
If there is a fan in the room (or adjacent rooms) the
spillage test be repeated with the fan running on full
power and all connecting doors between the fire and fan
left open.
If there are problems, the chimney/flue may require
attention. Isolate the stove and seek expert advice.
The stove will produce an odour and/or smoke for the
first few hours of use. Please ventilate the room.
Technical manual “1183”
9
Belfort GP - ref. 154 05 16
Installation instructions
Summary of Contents for BELFORT GP 154 05 16