2. Installation instructions

The appliance should only be installed by a
professional engineer, in the strict application of
normal practices and all safety precautions. The
installation must be carried out according to the
Standards and the Building Regulations.

2.1

Check the stove

Check the stove immediately after reception.

Ensure that the appliance conforms to the type of gas
distributed and the method of venting away the
combustion products as per the indications on the
appliance’s information plate and the gas setting label
affixed to the appliance when it leaves the factory.

The appliance is adjusted and sealed in accordance
with category (G31)

I

3P.

Notify the vendor if there is any damage or fault.

2.2

Ventilation

The premises should be in accordance with the building
regulations.

Ventilation

: The ventilation rate should be of at least

22 m

3

/h.

This gas stove is rated at less than 7kW; it therefore
does not normally require additional ventilation in the
room to conform to BS 5871 pt.2. However it is
important that adequate air for complete combustion is
available, and also if other gas appliances or extractor
fans are fitted in the same room or adja-cent area, then
it will be necessary to refer to BS 6714 and BS 5440
: p t . 2 . t o a s c e r t a i n t h e a d d i t i o n a l v e n t i l a t i o n
requirements.

2.3

Clearance requirements

The stove must stand on a fireproof hearth, which must
be of a non-combustible material with a minimum
thickness of 12 mm and extend 150 mm in front of the
stove.
The hearth must not be capable of inadvertent covering
by a rug or carpet. This may be achieved by either the
hearth being 50 mm above the level of the floor, or a
fender or kerb around the hearth to a height of 50 mm.
The appliance must not be fitted against a rear wall
constructed from a combustible material; a gap of
300 mm should be given all round the stove before
combustible materials may be used in the wall
construction.
If the appliance has to be located in an opening, the
minimum clearance from non-combustible materials is
shown in the figure.
The stove must be located at least 280mm from any
combustible materials.
A combustible shelf may be fitted over the appliance, if
in the case of a 150 mm or less deep shelf, there is at
least 280 mm clearance above the top of the stove. The
shelf depth may increase at the same rate as the
increase in clearance.

A

B

100

250

150

280

200

330

250

350

300

400

(i.e. a shelf depth of 200mm would require a clearance
of 330mm).

If the appliance has to be located in an opening, there
must be a clearance of at least 50 mm at the left hand of
the appliance, 50 mm at the back of the appliance and
50 mm above from any non-combustible materials. This
distance must be extended to a mininum clearance of
80 mm from any combustible materials.
There should ideally be a minimum gap of 150 mm at
the right hand side of the stove (this will ensure the best
p o s s i b l e a c c e s s t o t h e c o n t r o l k n o b ) . T h i s
measurement may be reduced to a minimum gap of
100 mm if needed however extra care should be taken
when operating the control knob when the appliance is
hot.

Technical manual “1183”

5

Belfort GP - ref. 154 05 16

Installation instructions

  

 

  

  

 

  

 

    

    

                       

                                    !

 !

 

Summary of Contents for BELFORT GP 154 05 16

Page 1: ...dress 2 rue Saint Gilles 68230 TURCKHEIM RC Colmar SIREN 439 330 325 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 43 Fax 00 333 28 43 43 99 Subject to...

Page 2: ...tructions for user 10 Manual Tap 10 Recommandations 10 Safety devices 11 Maintenance 11 Trouble shooting 11 Spare parts 12 FRANCO BELGE congratulates you on your choice FRANCO BELGE which has been gra...

Page 3: ...l be limited to the supply of the appliance 1 Description of the unit 1 1 Package The package will contain the following parts Belfort Stove inc Burner Logs kit FB 0516 or Coals kit FC 0516 1 2 Option...

Page 4: ...se performance and safety Installation of your stove must comply with current building regulations Franco Belges therefore recommend that a CORGI engineer be employed for this task Taking particular n...

Page 5: ...the stove The hearth must not be capable of inadvertent covering by a rug or carpet This may be achieved by either the hearth being 50 mm above the level of the floor or a fender or kerb around the he...

Page 6: ...on to the stove or within 1 meter of the appliance An 8mm nut and olive is supplied with the stove for the final pipe joint A gas supply isolation tap must be installed in the supply pipework in a loc...

Page 7: ...red with the appliance in the full rate position 2 8 Door Lock Technical manual 1183 7 Belfort GP ref 154 05 16 Installation instructions Figure 4 Door Lock 1 Safety screw 2 Male spanner 2 5 6 face 3...

Page 8: ...sponsibility for any injury sustained whilst handling hot ceramics Instructions for the layout of the prefixed ceramic matrix and loose coals for Belfort Flueless Stove Coal Layout Parts 1 Ceramic mat...

Page 9: ...ore the installed stove is left with the customer Carry out the test by first closing all doors and windows in the room containing the stove Ensure that the fire is burning at full rate for a minimum...

Page 10: ...appliance is now burning at its highest operating output Running the appliance at low setting Ignite permanent pilot and run appliance at High setting for a minimum of 10 minutes as shown above With...

Page 11: ...or performing correctly Ensure the pilot flame is the correct size for the type of gas The flame should be focused on the thermocouple probe The pilot flame will have been set correctly in the factor...

Page 12: ...Top plate X 01 3 327801 00 Clamp X X X X X 01 4 303860 MK Flue collar X 01 4 303860 MP Flue collar X 01 4 303860 RH Flue collar X 01 4 303860 EF Flue collar X 01 4 303860 79 Flue collar X 01 5 306281...

Page 13: ...902 EF Ash pan guide X 01 26 327902 79 Ash pan guide X 01 27 189713 Screw H M8X30 X X X X X 01 28 181632 Rope DIAM 6 X X X X X 0 90 m 29 181602 Ceramic rope DIAM 8 X X X X X 1 m 30 181614 Ceramic rope...

Page 14: ...14 Technical manual 1183 Belfort GP ref 154 05 16 Spare parts 0 1 2 0 1 2 0 2 1 1 0 2 0 1 2 Figure 6 Spare parts view...

Page 15: ......

Page 16: ...of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact w...

Reviews: