3. Instructions for user
Appliance 154 05 16 is set for natural gas (G31) and
sealed in accordance with category
I
3P.
A qualified installer must connect and commission
the appliance in accordance with the prevailing
regulations; otherwise the guarantee is void.
Warning: You are strongly advised to protect
unsupervised young children and handicapped
people from the high temperature reached by the
accessible operating surfaces and in particular the
glass.
The ignition and adjustment knob is on the bottom
right of the appliance. The pilot light is to the front
of the burner, under the matrix.
3.1
Manual Tap
•
Igniting the Pilot Light
Turn the Right-hand knob slightly anti-clockwise
towards the ignition position until reaching stop,
depress and hold for five seconds (only pilot gas flows).
Whilst still depressed, turn further in an anti-clockwise
direction to activate the piezo. If the pilot does not light,
repeated immediately.
Continue to keep
t h e
k n o b
depressed for a
f u r t h e r
1 0
s e c o n d s , a f t e r
the pilot has been
lit.
Upon releasing
t h e k n o b , t h e
permanent pilot will remain lit, if not return to off position
and repeat.
•
Running the appliance at high output
Ignite permanent pilot as shown in “Igniting the pilot
light”.
Tu r n
t h e
R i g h t - h a n d
c o n t r o l
k n o b
anti-clockwise to
the setting, which
shows the larger
flame. Turn the
Left-hand control
knob anti-clockwise to the highest setting (large flame).
The appliance is now burning at its highest operating
output.
•
Running the appliance at low setting
Ignite permanent pilot and run appliance at “High”
setting for a minimum of 10 minutes as shown above.
W i t h
t h e
Left-hand control
k n o b
a t
t h e n
highest setting,
r o t a t e
i n
a
c l o c k w i s e
direction to the
l o w e s t
s e t t i n g
(filled circle).
The appliance is now operating at its lowest operating
output.
•
Extinguishing the appliance back to permanent
pilot setting
F r o m a n y h e a t
setting, turn the
Right-hand knob
i n a c l o c k w i s e
direction to the
“ P i l o t ” p o s i t i o n
( t h e
s m a l l e r
flame).
•
Extinguishing the appliance fully
F r o m a n y h e a t
setting, turn to
“ P i l o t ”
a s
i n
“ E x t i n g u i s h i n g
t h e
a p p l i a n c e
b a c k
t o
permanent pilot
setting”. Depress
the same knob
slightly and turn clockwise to “Off” position (filled circle).
3.2
Recommandations
•
Whenever you ignite the appliance, ensure that the
pilot light’s flame is long enough (2-3cm) to light the
burner rapidly. Too long a delay in ignition can become
noisy and even dangerous. When the flame seems too
short, notify your heating engineer so that he can clean
the pilot light.
•
Close the safety tap when the stove is not used.
•
Under no circumstances should the appliance be
operated with the door open or the door glass
damaged.
•
If you smell gas : Do not smoke ! Avoid naked
flames ; do not use electric devices
. Open windows
and doors, close the gas tap and call your installer way
from the scene.
Never look for gas leaks with a naked flame.
F
This appliance produces heat and may cause
severe burns if touched
KEEP CHILDREN AWAY.
10
Technical manual “1183”
Belfort GP - ref. 154 05 16
Instructions for user
¶
¶
¶
¶
¶
Summary of Contents for BELFORT GP 154 05 16
Page 15: ......