32
Check if the electrical installation is proper to bring the
appliance in operating condition. If electricity installation
is not suitable, call an electrician and plumber to arrange
the utilities, as necessary. Manufacturer shall not be held
responsible for damages caused by operations
performed by unauthorized persons.
WARNING: It is customer’s responsibility to
prepare the
location the product shall be placed on and also to have
the electrical installation prepared.
WARNING: The rules in local standards about electrical
installations shall be followed during product installation.
WARNING: Check for any damage on the appliance
before installing it.
Do not have the product installed if it is damaged.
Damaged products cause a risk for your safety.
Product is designed in accordance with the kitchen counters supplied from market.
A safe distance should be left between the product and kitchen walls and furniture. If hood/aspirator will
be installed over your appliance, obey to the recommendation of hood / aspirator manufacturer for assembly
height. (min. 65 cm)
The gap that built in hob is to be placed on the counter should be cut in line with built in hob installation
dimensions.
For installation of the product, the rules specified in local standards related to electricity should be complied.
Ventilation of room
The air needed for burning is received from room air and the gases emitted are given directly in room.
For safe operation of your product, good room ventilation is a precondition. If no window or room to
be utilized for room ventilation is available, additional ventilation should be installed. However, room
has a door opening outside, it is no needed to vent holes.
Room size
Ventilating opening
Smaller than 5 m³
min. 100 cm²
Between 5 m³ - 10 m³
min. 50 cm²
Bigger than 10 m³
no need
In basement or cellar
min. 65 cm²
6.
INSTALLATION OF BUILT IN HOB