15. SPECIFICATION

3. Storage

If the unit is planned to be out of operation for a longer period of time, clean the filters before putting them back in positions. The unit has to be stored 

in upright position at all times. Do not put any heavy objects on the unit. Protect the air conditioner with plastic cover, if possible.

4. Transport

During transport, it is best to keep the unit in upright position. If it is not possible, lay it on its right side. Upon arrival in destination, swiftly put the unit 

back in upright position and wait no less than 4 hours before starting in cooling mode. To ensure maximum safety, inspect the power cable regularly. 

In case it is damaged during operation, contact authorised repair service to replace the cable.

SPECIFICATION

FSC12H

Cooling performance

3,52 kW

Heating performance

2,78 kW

Drying performance

28 l / 24 h

Nominal power consumption - cooling / heating

1,34 / 1,1 kW

Nominal current

4.5 A

Air flow

400m

3

/h

Temperature adjustment range - cooling / heating

16-31ºC / 16-31ºC

Permissible ambient temperature range - cooling / heating

7-35ºC / 7-35ºC

Refrigerant

R290a (0,29 kg)

Noise level (acoustic pressure)

51 db(A)

Dimensions: W x D x H

470 x 382 x 770 mm

Net weight

31,5 kg

Safety standard

CE

Auto Restart

yes

Energy Efficiency Rating (EER) - cooling / heating

2,61 / 2,30

Energy class

A/A

In case of any problem with the unit, answer the following questions.

1. Has the unit been out of operation for at least 2 hours?

2. Is the unit’s power cable connected to an electrical socket?

3. Are all fuses OK?

4. If so, turn the unit off for 3 minutes to check whether the problem has been solved. Restart the unit.

5. Check whether the water tank is full.

Environment. Take care of it

Cardboard box should be delivered to a paper waste collection company. Any polyethylene (PE) bags should be put in the plastic waste 

container; any plastic components should be delivered to a waste recycling company. Any metal components should be delivered to a 

scrap collection company. The authorities responsible for organisation of recyclable waste collection spots as well as information on their 

locations are Communal/Municipal Offices and County Offices.

FRAL SUPER COOL FSC12H

PORTABLE AIR CONDITIONER

Subject to the right to make technical changes and printing errors 06/2020

Summary of Contents for SUPER COOL

Page 1: ...USER S MANUAL LOCAL PORTABLE AIR CONDITIONER FRAL SUPER COOL FSC12H PORTABLE AIR CONDITIONER FRAL SUPER COOL Mod FSC12H INST _PL_IT_EN_DE_FSC12H_WER 1...

Page 2: ...er it has been shut down Otherwise the unit may sustain damage Do not turn on off the unit only by putting taking the plug in out of the socket Use the ON OFF button located at the unit s display The...

Page 3: ...turn off the unit by pulling the power plug Warning Additional hazard is possible if the unit is used incorrectly Ensure your personnel is appropriately trained Warning The unit is not a toy and cann...

Page 4: ...s warranty Make sure that hot air flows out freely from the outlet pipe Do not extend the hot air pipe beyond its maximum length of 2 metres If extended the unit s temperature cannot exceed 32 C Other...

Page 5: ...mmend to attach the hot air pipe to the windowl window kit is available as an option Partially open the window and put in the window adapter vertically or horizontally Connect the pipe to the adapter...

Page 6: ...adjusted CAUTION While operating as a drying unit the product does not provide cooling performance Do not connect the pipe when the unit is operated in drying mode The drying mode is recommended for...

Page 7: ...ame time Do not put batteries in fire this may cause an explosion INFORMATION ON CORRECT DISPOSAL OF BATTERIES ACCORDING TO EUROPEAN DIRECTIVE 2006 66 EU and amendment of the Directive 2013 56 EU Repl...

Page 8: ...N MODE INDICATOR VENTILATION TEMPERATURE AND TIME FEATURE INDICATOR SLEEP NIGHT MODE FAN OPERATION INDICATOR TEMPERATURE AND TIME DISPLAY FEATURE INDICATOR SWING FEATURE INDICATOR TIMER OPERATION MODE...

Page 9: ...EEP mode cannot be started in the ven tilation mode TEMPERATURE AND TIME ADJUSTMENT BUTTON The temperature range is adjustable from 16 C to 30 C Temperature up 1 This allows to adjust temperature set...

Page 10: ...cleaning it may damage its internal components or cause a short circuit Issue Error Cause Solution FL Water tank full Drain the tank If the error persists contact authorised repair service E1 Indoor...

Page 11: ...ent temperature range cooling heating 7 35 C 7 35 C Refrigerant R290a 0 29 kg Noise level acoustic pressure 51 db A Dimensions W x D x H 470 x 382 x 770 mm Net weight 31 5 kg Safety standard CE Auto R...

Reviews: