INST._PL_IT_EN_DE_FSC12H_WER.1
30
15. SPECIFICATION
3. Storage
If the unit is planned to be out of operation for a longer period of time, clean the filters before putting them back in positions. The unit has to be stored
in upright position at all times. Do not put any heavy objects on the unit. Protect the air conditioner with plastic cover, if possible.
4. Transport
During transport, it is best to keep the unit in upright position. If it is not possible, lay it on its right side. Upon arrival in destination, swiftly put the unit
back in upright position and wait no less than 4 hours before starting in cooling mode. To ensure maximum safety, inspect the power cable regularly.
In case it is damaged during operation, contact authorised repair service to replace the cable.
SPECIFICATION
FSC12H
Cooling performance
3,52 kW
Heating performance
2,78 kW
Drying performance
28 l / 24 h
Nominal power consumption - cooling / heating
1,34 / 1,1 kW
Nominal current
4.5 A
Air flow
400m
3
/h
Temperature adjustment range - cooling / heating
16-31ºC / 16-31ºC
Permissible ambient temperature range - cooling / heating
7-35ºC / 7-35ºC
Refrigerant
R290a (0,29 kg)
Noise level (acoustic pressure)
51 db(A)
Dimensions: W x D x H
470 x 382 x 770 mm
Net weight
31,5 kg
Safety standard
CE
Auto Restart
yes
Energy Efficiency Rating (EER) - cooling / heating
2,61 / 2,30
Energy class
A/A
In case of any problem with the unit, answer the following questions.
1. Has the unit been out of operation for at least 2 hours?
2. Is the unit’s power cable connected to an electrical socket?
3. Are all fuses OK?
4. If so, turn the unit off for 3 minutes to check whether the problem has been solved. Restart the unit.
5. Check whether the water tank is full.
Environment. Take care of it
Cardboard box should be delivered to a paper waste collection company. Any polyethylene (PE) bags should be put in the plastic waste
container; any plastic components should be delivered to a waste recycling company. Any metal components should be delivered to a
scrap collection company. The authorities responsible for organisation of recyclable waste collection spots as well as information on their
locations are Communal/Municipal Offices and County Offices.
FRAL SUPER COOL FSC12H
PORTABLE AIR CONDITIONER
Subject to the right to make technical changes and printing errors 06/2020