4. PORTABLE AND EASY TO USE

• The unit can be easily transported from one room to another.

• The air capacity is adjusted with three ventilation levels available.

• Installation by a qualified service is not required.

• All you need is to connect it to an electrical socket with parameters of 220-240V and 50Hz.

• The air outlet pipe may be stored in the unit during transport or with the air conditioner not operated at the moment.

• Do not connect the hot air pipe to any air ducts. It may cause the unit to sustain damage not covered with its warranty. Make sure that hot air flows 

out freely from the outlet pipe.

• Do not extend the hot air pipe beyond its maximum length of 2 metres. If extended, the unit’s temperature cannot exceed 32°C. Otherwise, it may 

cause the unit to sustain damage not covered with its warranty.

5. THIS DELIVERY SHOULD INCLUDE:

1 x Central unit   

1 x Remote control  

1 x Large flat-headed pipe end 

1 x Air discharge pipe 1.5 m, 15cm diameter

1 x Hot air pipe connector   

1 x Window adapter 

1 x Water discharge hose 

6. UNIT DESCRIPTION

Control panel

Cold air outlet

Grip holes

Hot air outlet

Condenser air intake plus air filter

Evaporator air intake plus air filter 

Power cable

Upper water drain valve 

Lower water drain valve 

Wheel casters

FRAL SUPER COOL FSC12H

PORTABLE AIR CONDITIONER

Summary of Contents for SUPER COOL

Page 1: ...USER S MANUAL LOCAL PORTABLE AIR CONDITIONER FRAL SUPER COOL FSC12H PORTABLE AIR CONDITIONER FRAL SUPER COOL Mod FSC12H INST _PL_IT_EN_DE_FSC12H_WER 1...

Page 2: ...er it has been shut down Otherwise the unit may sustain damage Do not turn on off the unit only by putting taking the plug in out of the socket Use the ON OFF button located at the unit s display The...

Page 3: ...turn off the unit by pulling the power plug Warning Additional hazard is possible if the unit is used incorrectly Ensure your personnel is appropriately trained Warning The unit is not a toy and cann...

Page 4: ...s warranty Make sure that hot air flows out freely from the outlet pipe Do not extend the hot air pipe beyond its maximum length of 2 metres If extended the unit s temperature cannot exceed 32 C Other...

Page 5: ...mmend to attach the hot air pipe to the windowl window kit is available as an option Partially open the window and put in the window adapter vertically or horizontally Connect the pipe to the adapter...

Page 6: ...adjusted CAUTION While operating as a drying unit the product does not provide cooling performance Do not connect the pipe when the unit is operated in drying mode The drying mode is recommended for...

Page 7: ...ame time Do not put batteries in fire this may cause an explosion INFORMATION ON CORRECT DISPOSAL OF BATTERIES ACCORDING TO EUROPEAN DIRECTIVE 2006 66 EU and amendment of the Directive 2013 56 EU Repl...

Page 8: ...N MODE INDICATOR VENTILATION TEMPERATURE AND TIME FEATURE INDICATOR SLEEP NIGHT MODE FAN OPERATION INDICATOR TEMPERATURE AND TIME DISPLAY FEATURE INDICATOR SWING FEATURE INDICATOR TIMER OPERATION MODE...

Page 9: ...EEP mode cannot be started in the ven tilation mode TEMPERATURE AND TIME ADJUSTMENT BUTTON The temperature range is adjustable from 16 C to 30 C Temperature up 1 This allows to adjust temperature set...

Page 10: ...cleaning it may damage its internal components or cause a short circuit Issue Error Cause Solution FL Water tank full Drain the tank If the error persists contact authorised repair service E1 Indoor...

Page 11: ...ent temperature range cooling heating 7 35 C 7 35 C Refrigerant R290a 0 29 kg Noise level acoustic pressure 51 db A Dimensions W x D x H 470 x 382 x 770 mm Net weight 31 5 kg Safety standard CE Auto R...

Reviews: