3. CONTROL 

Signalling panel 

 

Units are provided with signalling light panel that indicates unit operational status. Below is 
reported a brief description of their meaning. 

 

Control panel 

 

The Electronic card with microprocessor, control many functions: 

 

 

 

 

 

  

 

 

 

 

 

 

Power LED

; it’s on when the machine is in the ON state. 

Alarm LED

; it’s on when an alarm comes on. It turns off if the alarm is reset. 

Working LED

; the LED is on when the compressor is running, blinks when the dehumidifier is 

waiting to restart or is in defrost. It’s switched off when, in the ON state, the set of desired 
humidity has been reached. 

 

ON/OFF function

; plugged into the outlet (with ground wire!), the display turns on and shows the 

relative humidity in the room. 
The machine is in the OFF state when the Power LED is off. It’s in the ON state when the Power LED 
is on. 
When OFF, to switch on the dehumidifier, simply press the POWER key and depending on the 
relative humidity set the machine starts working. 
When the machine reaches the level of required moisture goes into stand-by mode: automatically 
stops but remains in the ON state (POWER LED on). 
If the humidity goes above the set point the dehumidifier starts again. 
When ON to put the dehumidifier in OFF just press the POWER button (the display continues to 
indicate the humidity in the room). 
Note: putting the machine OFF and immediately ON, the compressor does not start immediately and 
the Run led starts to flash. After a time of 210 seconds the machine restarts. 

HUMIDITY/TEMPERATURE SET function

; press one of the SET-/ +: the display starts flashing to 

indicate the humidity set; continuing to press SET-/ + you can bring to the set of required moisture 
(from 30% to 80%). After 4 seconds the display stops flashing and the new set of moisture is 
detected by the control unit. 
It’s possible to make the machine works regardless of the degree of moisture holding SET- until the 
message "Cont" appears. 

HOUR COUNTER

: to show on the display the machine operating time push switch HOURS. 

Summary of Contents for FDKA100.1

Page 1: ...M FDKA100 1 03 26 09 2017 DEUMIDIFICATORI DEHUMIDIFIERS FDKA100 1 MANUALE D USO E MANUTENZIONE USE AND MAINTENACE MANUAL M FDKA100 1 03 26 09 17...

Page 2: ...should be positioned with the sides against a wall and the inlet and discharge perpendicular to the wall Do not insert any objects into the inlet or discharge If service is required call a qualified t...

Page 3: ...to the room at a little bit higher temperature and lower Relative Humidity If the room temperature is lower than about 70 F the condensed moisture become ice In this case every roughly 30 minutes a de...

Page 4: ...mply press the POWER key and depending on the relative humidity set the machine starts working When the machine reaches the level of required moisture goes into stand by mode automatically stops but r...

Page 5: ...essary to make a cleaning of the warm heat exchanger condenser by using compressed air This operation must be done by a specialized technician This cleaning will improve the performances and the long...

Page 6: ...arge a Confirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will for...

Page 7: ...ard Defrosting Control System electronic Hot gas defrosting control system termost electronic Condensed Water Draining Pipe Connection 3 4 M Functioning Relative Humidity Range Temperature range 33 8...

Page 8: ...R PURPLE ORANGE WHITE BROWN BLUE BLUE FAN SOLEDOID VALVE ELECTRICAL BRIDGE 2 ELECTRICAL BRIDGE 3 BLU BLUE R G A E V PUMP T1 T2 T3 0105 UR BLUE POWER SUPPLY 115V 60HZ PCB 115V 60HZ TRANSFORMER 115V 220...

Page 9: ...a defect in workmanship or material These warranties do not apply for loss or damage caused by accident fire abuse misuse improper installation leaking modification misapplication weather freezing lac...

Page 10: ...also have other rights which vary from state to state Some states do not allow limitations on warranties or on remedies for breach In such states the above limitations may not apply to you FOR CANADIA...

Page 11: ...the unit to the condensate pump Dehumidifier Drain Fitting Level of Dehumidifier Drain Fitting drain drain Make sure no part of the hose is higher than the bottom of the drain fitting Note The drain...

Page 12: ...tting IMPORTANT The drain hose from dehumidifier to pump must run downward and stay below the level of dehumidifier drain fitting Tubing line from pump can run up to 20 feet upward and out into drain...

Reviews: