Fral FDK54 Use And Maintenance Manual Download Page 6

M.FDK54-05 UK Manual 26/09/2017 

 

 

Warning

:   Never apply an external source of heat to melt ice off coil. 

 

Maintenance 

– Annual Inspection of Coils and drain line is required. 

 

1.

 

Unplug  Unit 

2.

 

Filter may be cleaned by 

a.

 

Vacuuming 

b.

 

Washing with warm, soapy water. Rinse and shake dry. 

3.

 

Coils may be cleaned by 

a.

 

Vacuuming the external surfaces of  coil 

b. 

Blowing compressed air from behind coils.   Hold air nozzle 6” away from coil to avoid damage. 

 

Warning

:   Do not steam clean refrigerant coils. 

 

4.

 

Plug in Unit 

5.

 

Test  Refrigerant  Charge 

a.

 

Confirm compressor is running and allow to run for minimum of 15 minutes 

i.

 

If under 70°F, a layer of ice will form on evaporator coils 

ii.

 

If over 70°F, a layer of frost or water droplets will form on coil 

6.

 

Test Defrost  System 

a.

 

Leave  unit  running  for  approximately  30  minutes  (45-55  minutes).  The  unit  should  enter  a 
defrost  mode  for  approximately  5  minutes.  The  unit  will  enter  a  defrost  mode  with    the 
compressor operating and fan off to defrost the coil. If the unit will not defrost, either 

i.

 

Control board may be defective 

ii.

 

Bypass valve may be defective 

7.

 

After routine  maintenance has been completed,  return humidistat to desired  setting. 

If any problems occur during routine maintenance, contact your contractor or the  factory. 

Summary of Contents for FDK54

Page 1: ...M FDK54 05 UK Manual 26 09 2017 DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL...

Page 2: ...t the room the dehumidifier should be positioned with the sides against a wall and the inlet and discharge perpendicular to the wall Do not insert any objects into the inlet or discharge If service is...

Page 3: ...om at a little bit higher temperature and lower Relative Humidity If the room temperature is lower than about 32 F the condensed moisture become ice In this case every roughly 30 minutes a defrost dev...

Page 4: ...s the POWER key and depending on the relative humidity set the machine starts working When the machine reaches the level of required moisture goes into stand by mode automatically stops but remains in...

Page 5: ...OF MACHINE Beforestartingthedehumidifier makesurethatthemachinehasbeenstandinginverticalpositionforat least5hours If one fails to observe this procedure irreparable damage may be caused to the compre...

Page 6: ...nfirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will form on coil...

Page 7: ...osting Control System electronic Hot gas defrosting control system termost electronic Condensed Water Draining Pipe Connection 3 4 M Functioning Relative Humidity Range Temperature range 33 8 F 89 6 F...

Page 8: ...2017 F PUMP PUMP E V R G A MARRONE BROWN 8 ELECTRIC DIAGRAM COMPRESSOR BLU BLUE BIANCO WHITE VIOLA PURPLE FAN BLU BLUE COM BLU BLUE E V FAN ARANCIONE ORANGE BLU BLUE FLOAT HPS LPS JUMP 1 JUMP 2 JUMP 3...

Page 9: ...aintenance all in accordance with the Owner s Manual Failure to meet any of these requirements will void this warranty Servicing of the Product by parties other than Aerus authorized representatives a...

Page 10: ...TIONS GUARANTEES OR REPRESENTATIONS BREACH OF CONTRACT NEGLIGENCE OR ANY OTHER LEGAL THEORY Such excluded damages include but are not limited to loss of profits or revenue and loss of the use of the p...

Page 11: ...te pump Dehumidifier Drain Fitting Level of Dehumidifier Drain Fitting drain drain Make sure no part of the hose is higher than the bottom of the drain fitting Note The drain elbow is spot welded to t...

Page 12: ...NT The drain hose from dehumidifier to pump must run downward and stay below the level of dehumidifier drain fitting Tubing line from pump can run up to 20 feet upward and out into drain WARNING Hose...

Reviews: