Fral FDK54 Use And Maintenance Manual Download Page 11

 

 

 

 
 

dr

GRAVITY DRAIN INSTALLATION

 

 

Step 

Level Unit 

Step 

Attach Drain Line

 

 

 
 
 

 

Use  adjustable 

feet to level unit

 

Screw female end of drain line 
onto Fral  drain.

 

The Fral dehumidifier comes 
with a fixed drain outlet 
underneath the machine, it is a 
standard garden hose

 

thread" (GHT), which is 3/4" 
diameter straight

 

 

 

Run line down to drain, 
condensate  pump or 
sump pump.

 

 

Note well: If the machine does not have adjustable feet, check that it is properly leveled.

 

 

Step 

Run Drain Line

 

 

Option 1: Gravity Drain Installation 

NOTICE:

 

It is very important to

 

get a 

constant gravity 

flow 

from the unit to 

the condensate pump.

 

 
 

 
 
 
 
 
 
 
 
 

Dehumidifier 

Drain Fitting

 

 
 
 
 

 

Level of Dehumidifier Drain Fitting

 

 

 

drain

 

 

 
 

drain

 

Make sure no part of 
the hose is higher 
than the bottom of the 
drain fitting.

 

 

Note: 

The drain elbow 

is spot welded to the 
base of the unit to 
allow proper venting 
of drain line.

 

IMPORTANT: 

The drain hose must run downward and stay below

 

the level of dehumidifier drain fitting.

 

 
 

 

Option : Gravity Drain Installation

 

 
 
 
 
 
 
 
 
 
 

Level of Dehumidifier Drain Fitting

 

WARNING: 

No part of hose can be above level of dehumidifier

 

drain fitting.  Water will not go above this level and will flood the

 

dehumidifier.

 

If any water leaks at 
this joint, please 
check for restrictions 
or low spots in drain 
line

 

 
 

Dehumidifier 

Drain Fitting

 

 

Siphon 1

 

 

 

Siphon 2

 

 

ain

 

 

 

WARNING:  

Double siphon is not allowed  because it not allow 

correct drainage  of  water

 

Summary of Contents for FDK54

Page 1: ...M FDK54 05 UK Manual 26 09 2017 DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL...

Page 2: ...t the room the dehumidifier should be positioned with the sides against a wall and the inlet and discharge perpendicular to the wall Do not insert any objects into the inlet or discharge If service is...

Page 3: ...om at a little bit higher temperature and lower Relative Humidity If the room temperature is lower than about 32 F the condensed moisture become ice In this case every roughly 30 minutes a defrost dev...

Page 4: ...s the POWER key and depending on the relative humidity set the machine starts working When the machine reaches the level of required moisture goes into stand by mode automatically stops but remains in...

Page 5: ...OF MACHINE Beforestartingthedehumidifier makesurethatthemachinehasbeenstandinginverticalpositionforat least5hours If one fails to observe this procedure irreparable damage may be caused to the compre...

Page 6: ...nfirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will form on coil...

Page 7: ...osting Control System electronic Hot gas defrosting control system termost electronic Condensed Water Draining Pipe Connection 3 4 M Functioning Relative Humidity Range Temperature range 33 8 F 89 6 F...

Page 8: ...2017 F PUMP PUMP E V R G A MARRONE BROWN 8 ELECTRIC DIAGRAM COMPRESSOR BLU BLUE BIANCO WHITE VIOLA PURPLE FAN BLU BLUE COM BLU BLUE E V FAN ARANCIONE ORANGE BLU BLUE FLOAT HPS LPS JUMP 1 JUMP 2 JUMP 3...

Page 9: ...aintenance all in accordance with the Owner s Manual Failure to meet any of these requirements will void this warranty Servicing of the Product by parties other than Aerus authorized representatives a...

Page 10: ...TIONS GUARANTEES OR REPRESENTATIONS BREACH OF CONTRACT NEGLIGENCE OR ANY OTHER LEGAL THEORY Such excluded damages include but are not limited to loss of profits or revenue and loss of the use of the p...

Page 11: ...te pump Dehumidifier Drain Fitting Level of Dehumidifier Drain Fitting drain drain Make sure no part of the hose is higher than the bottom of the drain fitting Note The drain elbow is spot welded to t...

Page 12: ...NT The drain hose from dehumidifier to pump must run downward and stay below the level of dehumidifier drain fitting Tubing line from pump can run up to 20 feet upward and out into drain WARNING Hose...

Reviews: