Fral FDK54 Use And Maintenance Manual Download Page 4

M.FDK54-05 UK Manual 26/09/2017 

 

 

3. CONTROL

 

 

Signalling panel

 

 

Units are provided with signalling light panel that indicates unit operational status. Below is reported a brief 
description of  their  meaning. 

 

Control panel

 

The  Electronic  card  with  microprocessor,  control many functions: 

 

 
 

Power LED

; it’s on when the machine is in the ON state. 

 
 
 

Alarm LED

; it’s on when an alarm comes on. It turns off if the alarm is reset. 

 

 
 

Working LED

; the LED is on when the compressor is running, blinks when the dehumidifier is 

waiting to restart or is in defrost. It’s switched off when, in the ON state, the set of desired 
humidity has been reached. 

 

 
 

ON/OFF function

; plugged into the outlet (with ground wire!), the display turns on and shows the 

relative humidity in the room. 
The machine is in the OFF state when the Power LED is off. It’s in the ON state when the Power LED 
is on. 
When OFF, to switch on the dehumidifier, simply press the POWER key and depending on the 
relative humidity set the machine starts working. 
When the machine reaches the level of required moisture goes into stand-by mode: automatically 
stops but remains in the ON state (POWER LED on). 
If the humidity goes above the set point the dehumidifier starts again. 
When ON to put the dehumidifier in OFF just press the POWER button (the display continues to 
indicate the humidity in the room). 
Note: putting the machine OFF and immediately ON, the compressor does not start immediately and 
the Run led starts to flash. After a time of 210 seconds the machine restarts. 

 

 

HUMIDITY/TEMPERATURE SET function

; press one of the SET-/ +: the display starts flashing to 

indicate the humidity set; continuing to press SET-/ + you can bring to the set of required moisture 
(from 30% to 80%). After 4 seconds the display stops flashing and the new set of moisture is 
detected by the control unit. 
It’s possible to make the machine works regardless of the degree of moisture holding SET- until the 
message "Cont" appears. 

 
 

 

HOUR COUNTER

: to show on the display the machine operating time push switch HOURS. 

Summary of Contents for FDK54

Page 1: ...M FDK54 05 UK Manual 26 09 2017 DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL...

Page 2: ...t the room the dehumidifier should be positioned with the sides against a wall and the inlet and discharge perpendicular to the wall Do not insert any objects into the inlet or discharge If service is...

Page 3: ...om at a little bit higher temperature and lower Relative Humidity If the room temperature is lower than about 32 F the condensed moisture become ice In this case every roughly 30 minutes a defrost dev...

Page 4: ...s the POWER key and depending on the relative humidity set the machine starts working When the machine reaches the level of required moisture goes into stand by mode automatically stops but remains in...

Page 5: ...OF MACHINE Beforestartingthedehumidifier makesurethatthemachinehasbeenstandinginverticalpositionforat least5hours If one fails to observe this procedure irreparable damage may be caused to the compre...

Page 6: ...nfirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will form on coil...

Page 7: ...osting Control System electronic Hot gas defrosting control system termost electronic Condensed Water Draining Pipe Connection 3 4 M Functioning Relative Humidity Range Temperature range 33 8 F 89 6 F...

Page 8: ...2017 F PUMP PUMP E V R G A MARRONE BROWN 8 ELECTRIC DIAGRAM COMPRESSOR BLU BLUE BIANCO WHITE VIOLA PURPLE FAN BLU BLUE COM BLU BLUE E V FAN ARANCIONE ORANGE BLU BLUE FLOAT HPS LPS JUMP 1 JUMP 2 JUMP 3...

Page 9: ...aintenance all in accordance with the Owner s Manual Failure to meet any of these requirements will void this warranty Servicing of the Product by parties other than Aerus authorized representatives a...

Page 10: ...TIONS GUARANTEES OR REPRESENTATIONS BREACH OF CONTRACT NEGLIGENCE OR ANY OTHER LEGAL THEORY Such excluded damages include but are not limited to loss of profits or revenue and loss of the use of the p...

Page 11: ...te pump Dehumidifier Drain Fitting Level of Dehumidifier Drain Fitting drain drain Make sure no part of the hose is higher than the bottom of the drain fitting Note The drain elbow is spot welded to t...

Page 12: ...NT The drain hose from dehumidifier to pump must run downward and stay below the level of dehumidifier drain fitting Tubing line from pump can run up to 20 feet upward and out into drain WARNING Hose...

Reviews: