Fral FDK54 Use And Maintenance Manual Download Page 2

M.FDK54-05 UK Manual 26/09/2017 

 

 

1.   SAFETY WARNINGS

 

 
 

 

 

The  FDK54  Series  Dehumidifier  must  always  be  connected  using  the  grounded  electrical  connection  as 
required  from  all  electrical  appliances.  The  warranty  is  voided  and  all  responsibility  for  the  operation  is 
born by the owner if non-grounded wiring is utilized. 

 

The FDK54 Dehumidifiers must  only be maintained and serviced by a qualified technician. 

 

The  FDK54  Dehumidifiers  are  intended  only  for  operation  when  oriented  with  the  unit  sitting  on  its  feet 
and  level.  Any  other  orientation  could  cause  water  to  come  in  contact  with  the  electrical  components. 
Remove  plug before  moving dehumidifier. If any water  may have spread throughout  unit, the  unit should 
be opened and allowed to dry thoroughly before  reconnected to electric and restarting. 

 

For  proper  operation,  neither  the  inlet  or    discharge  should    be  positioned  against  a  wall.  The  inlet 
requires a minimum of 12” clearance and the discharge needs a minimum of  24” clearance. 

 

For  proper  diffusion  of  air  throughout  the  room,  the  dehumidifier  should  be  positioned  with  the  sides 
against a wall and the inlet and discharge perpendicular to the wall. 

 

Do  not  insert  any  objects  into  the  inlet  or  discharge.  If  service  is  required,  call  a  qualified  technician.  All 
work on unit should be down with the unit “off” and unplugged. 

 

Do not use water to clean unit exterior.   Only use a damp cloth with unit unplugged. 

 

Do not use unit as shelf or device to hang clothes.   This could cause damage to unit. 

 

The  inlet  filter  generally  needs  cleaned  once  per  month.  Check  unit  on  a  weekly  basis  to  ensure  that 
more frequent  cleaning is  not required. 

 

Identification: 

 

For future reference, write down the model,  serial number, date of purchase and use this  information whenever 
corresponding  concerning  your  dehumidifier. 

 

Model Number 

  

 

Serial Number 

 

Date of Purchase 

 

 

 

Warning

 

115 Volts AC may cause serious injury from electric shock. 

 

1.  Disconnect electrical power before servicing 
2.  Plug unit only into grounded electrical outlet 
3.  Do not use extension cord 
4.  Do not use plug adapter 

 

Power Supply: 

115V, 60 Hz 
AC Only 1 Phase 

Outlet Requirement: 

3-Prong 

Circuit Protector: 

Only compressor thermal and overload relay protector 

Circuit Breaker 

Fuse on PCB supply 

Summary of Contents for FDK54

Page 1: ...M FDK54 05 UK Manual 26 09 2017 DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL...

Page 2: ...t the room the dehumidifier should be positioned with the sides against a wall and the inlet and discharge perpendicular to the wall Do not insert any objects into the inlet or discharge If service is...

Page 3: ...om at a little bit higher temperature and lower Relative Humidity If the room temperature is lower than about 32 F the condensed moisture become ice In this case every roughly 30 minutes a defrost dev...

Page 4: ...s the POWER key and depending on the relative humidity set the machine starts working When the machine reaches the level of required moisture goes into stand by mode automatically stops but remains in...

Page 5: ...OF MACHINE Beforestartingthedehumidifier makesurethatthemachinehasbeenstandinginverticalpositionforat least5hours If one fails to observe this procedure irreparable damage may be caused to the compre...

Page 6: ...nfirm compressor is running and allow to run for minimum of 15 minutes i If under 70 F a layer of ice will form on evaporator coils ii If over 70 F a layer of frost or water droplets will form on coil...

Page 7: ...osting Control System electronic Hot gas defrosting control system termost electronic Condensed Water Draining Pipe Connection 3 4 M Functioning Relative Humidity Range Temperature range 33 8 F 89 6 F...

Page 8: ...2017 F PUMP PUMP E V R G A MARRONE BROWN 8 ELECTRIC DIAGRAM COMPRESSOR BLU BLUE BIANCO WHITE VIOLA PURPLE FAN BLU BLUE COM BLU BLUE E V FAN ARANCIONE ORANGE BLU BLUE FLOAT HPS LPS JUMP 1 JUMP 2 JUMP 3...

Page 9: ...aintenance all in accordance with the Owner s Manual Failure to meet any of these requirements will void this warranty Servicing of the Product by parties other than Aerus authorized representatives a...

Page 10: ...TIONS GUARANTEES OR REPRESENTATIONS BREACH OF CONTRACT NEGLIGENCE OR ANY OTHER LEGAL THEORY Such excluded damages include but are not limited to loss of profits or revenue and loss of the use of the p...

Page 11: ...te pump Dehumidifier Drain Fitting Level of Dehumidifier Drain Fitting drain drain Make sure no part of the hose is higher than the bottom of the drain fitting Note The drain elbow is spot welded to t...

Page 12: ...NT The drain hose from dehumidifier to pump must run downward and stay below the level of dehumidifier drain fitting Tubing line from pump can run up to 20 feet upward and out into drain WARNING Hose...

Reviews: