![Fraco SEP-5000 User Manual Download Page 61](http://html1.mh-extra.com/html/fraco/sep-5000/sep-5000_user-manual_2326220061.webp)
Transport platform
SEP Serie
SEP u
ser’s manual Page 61 of 89
Doc no. RD-7243-MA-001-02
7.15.
Using the derivation adaptor
Activation of the emergency centrifugal brake:
(S
EE PREVIOUS PAGE
)
Travel end buffer:
•
If the platform exceeds the position of the
"FINAL POSITION"
travel end detector and
triggers the buffer activation detector, this will turn off the safety line and will prevent any
platform movement. To correct the situation, connect the derivation adaptor in the port of the
panel (
CC1
) and raise the platform to completely free the
"FINAL POSITION"
travel end
detector.
Tension on the power supply cable:
•
If the power supply cable gets stuck or becomes taut, a detector sends a signal to the safety
line and will prevent any movement of the plateform. To correct the situation, plug the
derivation adaptor in the port of the panel (
CC1
) and raise/lower the platform until the cable is
free.
(RD-7243-BE-112)
Figure 40
– Derivation adaptor