33
8.
Milk frother
– any calls related to “milk frother not frothing” caused by incorrectly cleaning frother,
incorrect assembly (including loss of o-rings) and wear of the o-rings.
9.
Milk frother
– any calls related to milk temperature or milk foam consistency as a result of incorrectly
adjustment of temperature or air valve, incorrectly assembled frother or incorrectly cleaning.
10.
Milk frother
– any calls related to “milk not frothing” caused by stale milk or milk with high protein content.
11.
Grinders
– the replacement of the grinder blades, any calls to reset portioning or coffee grind or to
jammed/obstructed blades.
12.
Water treatment
– any calls to replace a water treatment unit (DSU)
13.
Knockout drawers
– any calls to repair jammed or broken runners as a result of negligence, malpractice
or misuse by the operator.
14.
Training
– Training on use and daily maintenance of the equipment is given at the time of installation.
Any calls for further training or for training on a day other than that of installation will be fully chargeable.
TECHNICAL SPECIFICATIONS
Voltage:
230Vac 50Hz
Power rating:
2.7Kw
Current rating:
13Amp
Min. inlet water pressure:
1Bar (100kPa)
Max. inlet water pressure:
6Bar (600kPa)
Boiler max working pressure:
2Bar (200kPa)
Boiler normal working pressure:
1.3Bar (130kPa)
Boiler safety valve set pressure:
1.6
– 1.8Bar (160-180kPa)
Expansion valve set pressure:
12Bar(1200kPa)
Pump set pressure:
9Bar(900kPa)
Boiler capacity:
7L
Overall dimensions:
450 x 375 x 550mm (HxWxD)
Weight:
35kg