30
STORAGE
The machine must be stored and stored at a temperature above 5°C, to prevent water in the
appliance freezing and causing damage.
NOTE:
If the appliance has frozen or is suspected to have been
stored at temperature below 5°C, the following procedures
must be performed.
1.
The appliance must be fully isolated from the mains electricity and water
supply.
2.
The appliance must be allowed to fully de-frost.
3.
All pipes, boiler, flow meter, manifold, group, solenoids and mains water
inlet hose must be inspected for damage/leaks, if any parts are found to
be damaged or leaking they must be replaced with new parts, it is
recommended that a trained service engineer inspects and tests the
appliance.
4.
If in doubt, contact Fracino to arrange for a trained service engineer to
inspect and test the appliance.
MAINTENANCE
SPECIAL PRECAUTIONS
WARNING:
Maintenance other that regular cleaning should only be performed by trained service
engineers. Failure to use trained engineers may invalidate warranty and may damage the machine.
WARNING:
Ensure the appliance has been fully isolated from the mains power supply before removing
any body panels.
WARNING:
Allow the machine to cool for at least an hour before removing any body panels or
components.
WARNING:
Ensure the boiler is fully de-pressurised by opening the steam valve(s)
!