5
- Up to 4 remote keypads for managing the system and totally/partially arming the system.
- Firmware updating from PC (locally) with a MOD-USB interface module.
- 250 stored events can be displayed with the date/ time/user/event displayed with
the set name for better tracking.
- Partialization, even by means of an electronic key, with RFID technology (up to 4 readers for a
total of 16 total keys).
- 10 codes available (1 Master code, 1 Installer code and 8 user codes that can be programmed).
Other features
- Bus length up to 1500 m.
- Anti-opening and anti-tearing protection.
- Sensor feeding activated even when the system is off.
- Specific circuit for external battery recharging.
- Walk Test Tamper function for maintenance.
- Timing block of the control unit if a false code is entered.
- Input/output time which can be programmed from 0 to 250 seconds.
- Battery control function.
- Line termination as single, double balance, normally closed, normally open,
all defined for each single line (NO by default also for expansions).
- 7 outputs that can be programmed on the control unit: 1 live (positive and
negative reference for sirens), 5 Open Collector (50 mA) configured by default but
that can also be programmed. Activation time, activation mode, activation delay and possibility
of associating key-user is also possible,
- 3 access levels: Installer/ 1 master user /8 users which can be modified,
- The lines can be configured as: instant alarm, burglar alarm, delayed alarm, input (key), 24h
alarm/panic alarm,
- Signals from the keypad LEDs: activation/ deactivation; electric network present;
tamper alarm; battery failure and expansion modules; alarm,
- 1 A feeder,
- Digital dialler with remote management (basic), Fast Format and Contact ID, 8 channels
available and 16 number phone book.
2. DESCRIPTION OF THE CONTROL UNIT
- 8 input lines which can be individually
programmed as normally closed or
normally open, single or double balan
ced.
- Anti-opening and anti-tear protection.
- Plastic case.
- 12V 2Ah battery available
- 12V 1A switching feeder.
- Alarm output of self-powered siren.
- Alarm output for a siren that is not self-
powered.
- 5 open collector outputs.
- Power protection against overloads,
short circuits and high voltage.
- All the inputs and outputs are filtered and protected against electrical and electrostatic
charges.
- Battery flat or disconnected detection circuit.
- Power for external devices, protected against overloads.
- Operating temperature: 0°C ÷ +40°C.
The following devices are available to complete the system:
- T8N-Light - control and programming keypad with alphanumeric backlit display.