10
OUT4
Open collector output, which can be programmed. Negative in the
event of activation. Max 50mA
OUT3
Open collector output, which can be programmed. Negative in the
event of activation. Max 50mA
OUT2
Open collector output, which can be programmed. Negative in the
event of activation. Max 50mA
OUT1
Open collector output, which can be programmed. Negative in the
event of activation. Max 50Ma Pre-configured output as SYSTEM
STATUS: the output is active when the system is armed
+B
Feeding point no. 2 – power supply to the input devices: 12Vcc
500mA max
+V_INT SIR
12 V live output which can be programmed. Programmed by default
as an intrusion alarm output. Max current 500 mA.
GND
Ground – negative of the power supply point
+REF
Live output, which can be programmed. Programmed by default as
a reference for the intrusion alarm.
+13.8V EXT_SIR
Battery charge power supply
J4 terminal board
Terminal
Features
+12V
Feeding point no. 3 –power supply of BUS devices 12Vcc 500mA max
BUS+
BUS line positive
BUS-
BUS line negative
GND
Ground – negative of the power supply point
J5 terminal board
Terminal
Features
LA
PSTN input line “A” - LINE
LB
PSTN input line “B” - LINE
DA
PSTN input line “A” - PHONE
DB
PSTN input line “B” - PHONE
Feeder terminal board
Terminal
Features
L (AC)
230Vca network PHASE input
N (AC)
230Vca neutral network input
Grounding wire connection
-V
GND power supply output
+V
+13.8V power supply output