background image

Greenfi re GF45 BioEnergy Stove

21

MAINTENANCE

Maintenance On The Combustion Fan

(Connected To The Chimney)

Diagram 21

Diagram 22

To clean the fl ywheel, use a steel brush shown on Diagram 22. Clean each 
wing of the fl ywheel, which will increase the pressure on the calibration 
indicator and will reduce vibrations caused by accumulated ashes.  

Maintenance On The 

Convection Fan

To reach the convection fan, remove the control panel (refer to diagram 
23 & 24). Then using a brush and a vacuum cleaner, clean each plastic 
impeller which will increase the hot air volume displacement in the room 
and reduce or eliminate any vibrations.

Diagram 23

Diagram 24

CONTROL 

PANEL

Maintenance On The 

Fuel Feeding System

At least once every year, empty the fuel hopper using a vacuum cleaner 
with fi lter, clean the fuel residues accumulated which are stuck at the 
bottom of the feed screw close to the nylon bushing (see Diagram 25).

Diagram 25

Inspection Of The Seals

At the start of each season, check gaskets on the door, hopper lid and 
ash door by using a strip of paper which you will slip at several places 
between the seal and the stove (see Diagram 26). Give the piece of paper 
a little tug and if it slips out easily the gaskets need to be replaced. Use 
only approved gasket and adhesive obtainable from your FPI dealer. A 
proper high temperature gasket adhesive is also required. 

Diagram 26

Information On How To

Clean The Chimney

At the start of each season or every 3 tons of fuel burned, check the 
accumulation of ashes inside the chimney. It is important to clean the 
full system including all lengths, T's and elbows.

Maintenance Of The Battery System

Check that the grips are well connected on the battery poles. Small test:  
start the stove without fl ame (cold). After 30 seconds, disconnect the plug 
which is connect to the wall socket. If the stove is functioning that means 
that the battery is well connected.  

Never place a battery directly on 

concrete as this can damage the battery. 

Type Of Cleaning Product To Use For The Glass

Always use a proper cleaning product which can be found at any hearth 
retailer, designed for high temperature glass.

NOTE:

 Only clean glass when the stove has completely cooled down.

MAINTENANCE

IMPORTANT NOTE:

Always disconnect the power to your stove

before doing any maintenace or repairs. 

There are two ways to clean the fan fl ywheel, either directly on the stove 
(Diagram 21) or  removing the fan from the stove (Diagram 22). 

Summary of Contents for Dell-Point GF45

Page 1: ...uel burning room heater Failuretofollowtheseinstructionscouldresultin property damage bodily injury or even death Contact local building or re of cials about restrictions and installation inspection r...

Page 2: ...about your product that are not covered in this manual please contact the FPI DEALER in your area Keep those FPI FIRES burning Safety Note If this stove is not properly installed a house re may result...

Page 3: ...INSTRUCTIONS Control Panel Functions 15 Starting Procedures 16 To Start Your Stove 16 Priming Stove Empty Hopper 16 Burning Wood Pellets Primed Hopper 16 To Stop Stove 16 Operation Guidelines for Burn...

Page 4: ...anieseach GF45 We have printed a copy of the contents here for your review The safety label is located on the back panel of the stove NOTE FPI units are constantly being improved Check the label on th...

Page 5: ...rebox in a negative pressure situation These are safety functions of the appliance INSTALLATION UNIT LOCATION 1 For optimum bene t from your appliance speak to your professional for help with your lo...

Page 6: ...e fans consume an average of 200 cfm which is more powerful than the combustionfanontheGF45 creatingnegativepressurearoundthestove To overcome this negative pressure the GF45 requires the installation...

Page 7: ...LLATION INSTALLATION UNIT DIMENSIONS CLEARANCES Alcove Ceiling height is 60 324mm measured from bottom of the unit Floor Protector of 0 84k factor minimum is required beneath the Hearth Please check w...

Page 8: ...or paved driveway which is located between two single family dwellings and serves both dwellings If the vent termination is accessible a certi ed guard shall be installed Local codes or regulations s...

Page 9: ...Green re GF45 BioEnergy Stove 9 INSTALLATION INSTALLATION HORIZONTAL TERMINATION Top View Side View...

Page 10: ...Green re GF45 BioEnergy Stove 10 INSTALLATION OUTSIDE VERTICAL TERMINATION INSTALLATION Side View...

Page 11: ...Green re GF45 BioEnergy Stove 11 INSTALLATION INSTALLATION VERTICAL TERMINATION Top View Side View Diagram 6...

Page 12: ...Green re GF45 BioEnergy Stove 12 INSTALLATION EXISTING CLASS A CHIMNEY INSTALLATION Diagram 7...

Page 13: ...Green re GF45 BioEnergy Stove 13 INSTALLATION INSTALLATION EXISTING MASONRY CHIMNEY Diagram 8...

Page 14: ...ere it left off upon restoration of power To facilitate the installation of a larger 12 volt battery we include exten sion alligator clip leads in the battery installation kit Note 12 volt batteries s...

Page 15: ...elect the appropriate fuel type that is going to be burned Heat Level Settings Select the desired heat level by pressing buttons Heat levels range from 1 to 5 for all fuels Service Allows you to chang...

Page 16: ...ht attempts To Start Your Stove To facilitate your start up and regardless of fuel being utilized in your stove you must use wood pellets as fuel for starting This will quickly raise the burner and ve...

Page 17: ...u continue to use the same fuel i e Corn or Wheat Burn pot fuel bed If you cannot see 5 of the burn pot wall above your fuel ember bed the level is too high refer to Diagram 9b in Low Fuel Ember Bed C...

Page 18: ...CLEAN THE COMBUSTION FAN FLYWHEEL X INSPECT THE SEALS X CLEAN THE CHIMNEY X INSPECT IGNITOR TUBES X COMPONENTS OF STOVE EACH START UP WEEKLY MONTHLY ANNUALLY REMOVE ASHES IN BURN POT X CHECK THE ASH R...

Page 19: ...er avoid the use of a domestic style vacuum cleaner with lter only when the stove is cold to remove the ashes accumulated around the burn pot Diagram 10 Clean the interior of the glass door Use the sh...

Page 20: ...corn or wheat can stick to the ash screws resulting in poor movement and ash removal Check by removing the ash extraction system or look inside the burn pot Diagram 16 Diagram 15 Step 2 Use a 9 16 wre...

Page 21: ...iagram 26 Give the piece of paper a little tug and if it slips out easily the gaskets need to be replaced Use only approved gasket and adhesive obtainable from your FPI dealer A proper high temperatur...

Page 22: ...ngs 5 levels of heat Electrical Min Capacity 25 amps 120 volts 120 volts or 240 volts AC 15 amps 240 volts Max Capacity 65 amps 120 volts 35 amps 240 volts 12 volts DC Min Capacity 1 8 amps 13 8 Volts...

Page 23: ...the startup procedures as listed in the manual System Shutdown Contact Dealer a The feed auger fuse is blown Unit will go into shutdown mode After shutdown the screen will display Fuse Error EFF b The...

Page 24: ...Pin 3 4 orange wires safety Pin 16 red wire Convection fan Pin 5 6 green wires safety Pin 17 black wire input Pin 7 black wire feed system Pin 18 white wire protection Pin 8 yellow wire feed system Pi...

Page 25: ..._________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________...

Page 26: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Page 27: ...er name purchase date model serial number problem parts requested Without this information the claim will be invalid Warranty is only valid if the maintenace schedule is followed as listed in the manu...

Page 28: ...Printed in Canada Copyright 2006 FPI Fireplace Products International Ltd All rights reserved...