Greenfi re GF45 BioEnergy Stove
23
TR
OUBLESHOO
TING
TROUBLESHOOTING
TROUBLESHOOTING
ERROR CODE
PROBLEM
SOLUTION
System Cooling
Temp Overshoot
The thermodisc temperature has exceeded 250F.
1st Time;
Hardware takes over and the unit goes
into shutdown mode.
2nd Time;
When the unit is restarted, hardware
takes over and the unit goes into shutdown
mode.
3rd Time;
When the unit is restarted, hardware takes
over and the unit goes into shutdown mode.
Allow the unit to shutdown and unit will auto-
matically restart.
Allow unit to shutdown. When screen displays
"Ready to restart", the user must reset the unit
by pressing the "STOP" button for 5 seconds.
Once unit is reset, restart unit.
Contact dealer, service is required.
System Shutdown
Check Fuel/Feed
When the temperature of the thermodisc falls below
110F, while in normal burning mode, the thermodisc
will trip and the unit will go into shutdown mode.
Allow unit to shutdown and check for fuel in
the hopper. Also ensure that the front door
and hopper lid are securely closed.
System Shutdown
Failed Startup
Initial startup did not reach 130F within the required
time, unit will go into shutdown mode.
Follow the startup procedures as listed in
the manual.
System Shutdown
Contact Dealer
a) The feed auger fuse is blown. Unit will go into
shutdown mode. After shutdown, the screen
will display "Fuse Error:EFF".
b) The ash auger fuse is blown. Unit will go into
shutdown mode. After shutdown, the screen
will display "Fuse Error:EFA".
c) If the glow plug fuse is blown, unit will go into
shutdown mode. After shutdown, the screen
will display "Fuse Error:EFG".
Contact dealer, service is required.
Contact dealer, service is required.
Contact dealer, service is required.
System Shutdown
Check Power
The input voltage is below 10.5V for more than 3
seconds. Unit will go into shutdown mode.
Allow unit to shutdown. When screen displays
"Ready to restart", the user must reset the unit
by pressing the "STOP" button for 5 seconds.
Once unit is reset, restart unit.
System Shutdown
Replace Key
The alternate fuel key has been missing for more
then 20 seconds. Unit will go into shutdown
mode.
Allow unit to shutdown. When screen displays
"Ready to restart", the user must reset the unit
by pressing the "STOP" button for 5 seconds.
Once unit is reset, insert the greenkey and
restart unit.
NOTE: Unit shutdown takes 120 minutes.
IMPORTANT:
Always disconnect the power to your stove before doing any maintenace or repairs.
Only a qualifi ed technician should take care of any electrical problems.