IN 5C08/12/15/18/24.
- 29 -
© Future Products Group
Refrigeration
cont.
REFRIGERATED CABINETS - SERVICING
XR40CX
Min & Max
Recorded
Temperature
Press and release the
key.
Lo
will be displayed followed by the minimum temperature recorded.
Press the
key again or wait 5s to restore the normal display.
Press and release the
key.
Hi
will be displayed followed by the maximum temperature recorded.
Press the
key again or wait 5s to restore the normal display.
XR40CX
Reset Max/Min
Temperature
Memory
Press the
SET
key for more than 3s, while the max. or min. temperature is
displayed. (
rSt
message will be displayed)
To confirm the operation the
rSt
message starts blinking and the normal
temperature will be displayed.
XR40CX
Display the Set-
point
To show the set-point value, press and immediately release the
SET
key.
Press and immediately release the
SET
key or wait for 5 seconds to display the
probe temperature again.
XR40CX
Change the
Set-point
To change the set-point value, press the
SET
key for more than 2 seconds;
The value of the set-point will be displayed and the °C or °F LED starts blinking;
To change the set value push the
or
arrows within 10s.
To memorise the new set-point value push the
SET
key again or wait 10s.
XR40CX
Start a Manual
Defrost
To start a manual defrost, press the
(DEF) key for more than 2 seconds.
XR40CX
Programming
Mode
Enter the Programming mode by pressing the
keys for 3s
(the °C or °F LED starts blinking).
•
Use the
or
keys to select the required parameter.
•
Press the
key to display its value.
•
Use the
or
keys to change its value.
•
Press
to store the new value and move to the following parameter.
To exit Programming mode, press
or wait 15s without pressing a key.
NOTE: the set value is stored even when the procedure is exited by waiting for
the time-out to expire.
Continued on next page