Mailing system
Opti
mail 30 – Service documentation
Zac Moody/Andrew Nagel Revision June 2005 optimail30 service mode chapter2 (dealer)
Page
13
FRANCOTYP-POSTALIA
S1: System
S
TEPS
:
Information about the Meter
Î
System
Shows system information
Meter Number
Shows the serial number of the meter
Software Version
Shows the current software version of the meter
Boot Loader Version
Shows the current Boot Loader version (this is similar to the bios on a PC)
Main board Version
Shows the current main board version in hexadecimal
Main Board Serial
Number
Shows the main board serial number
Flash Sign Byte
R & D use only
Imprint data version
Shows current cliché data version pertaining to USPS standards
NV Ram Version
Shows the current NV Ram Version which is important to know when performing
software upgrades
Print Head Resistance
Shows the current resistance of the installed print head. Can also be checked from the
sticker on the actual print head
Temperature
Shows the current temperature inside the meter
S2: Security Device
S
TEPS
:
Information about the Meter
Î
Security Device
Shows PSD information
The Information shown is as follows:
Security Device ID
PSD Unit ID
Status
Status (State) see chapter 3: “PSD“
Self Test Results
Results of the internal security device self test
HS Loop Det. Enabled
Yes = HS-Loop switch of the meter is controlled
HS Loop Det. Active
No = HS-Loop switch of the meter make no alert
Batt Det. Enabled
Manipulation security feature to check if the PSD-battery is present
(default: Yes = it will be checked). If the battery would be replaced e.g. for
manipulation, then the PSD get into the state „defect“
Batt Det Active
Battery-security check detect „Alert“ (No = everything is ok)
TAM Det Enabled
Manipulation security feature to check if the PSD was open
(No = no security check).
TAM Det Active
Yes = housing manipulation of the PSD will be displayed – but it makes no
matter, because we didn’t control this at this time
This sensor is not implemented that’s why we display always “open”.
V Batt A (intern)
Voltage of the PSD-battery in mV
V Batt B (extern)
Voltage of the external-battery in mV
ADC Vcc 3, 5, 8
Internal main voltage in the PSD
Tempsensor Current
Value of the internal temperature sensors
Tempsensor Low Limit
Value of the internal temperature sensors
Tempsensor Up Limit
Value of the internal temperature sensors
Current Date/Time
Date and Time
Time Zone
Time Zone (e.g. D=1)
Time Offset
Manual time setting (e.g. User-Mode, Service-Mode)
Code Verification key
Hash
R & D use Only
Country Code
ISO-Country code (e.g. Germany=276)
Prod.Test Success
Factory Only
Magic Number
R & D only