Mailing system
Opti
mail 30 – Service documentation
Zac Moody/Andrew Nagel Revision June 2005 optimail30 service mode chapter2 (dealer)
Page
10
FRANCOTYP-POSTALIA
S3: Settings
Î
Security Device
S1: Reset HS-Loop
Steps:
Settings
Î
Security Device
Î
Reset HS-Loop
After opening the machine casing the HS-Loop can be reset.
(HS = housing security or also Casework Security)
After resetting the HS-Loop a zero reset is required.
S2: Authorize
Steps:
Settings
Î
Security Device
Î
Authorize
The security device status changes from “Initialized” to “Authorized”.
S3: Re-Authorize (Remote)
Steps:
Settings
Î
Security Device
Î
Re-Authorize (Remote)
This feature is used to up date the customer’s Zip code after they have changed addresses.
S4: Re-Initialize
Steps:
Settings
Î
Security Device
Î
Re-Initialize
This feature is used after withdrawing the meter from one customer and installing into a new customer.
S5: Echo
Steps:
Settings
Î
Security Device
Î
Echo
Refer to Test function section of this manual
S6: Secure-Echo
Steps:
Settings
Î
Security Device
Î
Secure Echo
Refer to Test function section of this manual
S7: Withdraw
Steps:
Settings
Î
Security Device
Î
Withdraw
Withdrawing the meter transfers the remaining credit from the meter into the customers TDC account
and the USPS are informed electronically of the withdrawal.
The following data is deleted during this process:
-Cost Accounts
-Type of mail endorsements (but not standard endorsements)
-Type of mail statistics
-Class of mail (This may be a new USPS requirement in the future)
-Advertisements
-Gravity calibration value
-Zip code
-HP / LP warnings
-Shift position
S8: Self test
Refer to Test function section of this manual
S9: Lock out Security Device
The Security Device
changes the status manually from “Valid” to “Authorized” Performing a zero reset
resets the lock out. (Used only if manipulation is suspected and inform TDC to also lock the account)