26
adjusting software). At this time, stir any joystick or dial lever
and the alarm sound will be automatically turned off. When the
"alarm time" is set to 0 minutes, the alarm function will be
cancelled.
Low power alarm
The battery voltage is lower than the set
alarm voltage
(default:10.6 V) , the remote control will issue
"didi" alarm, power indicator will flashing in red. When the
battery voltage rises to
alarm recovery voltage
, the alarm will
stop. When the battery voltage drops to
low voltage shutdown
voltage
, the remote control will automatically shut down to
enter protection mode. When
alarm voltage
is set to 0V, no
low power alarm function.
1.Alarm recovery voltage is 0.3v higher than the set alarm voltage.
2.Low-voltage shutdown voltage is 0.3v lower than the set alarm
voltage.
7. V20 Video Transmission System
Operation
7.1 Data link Serial Port Operation
Default baud rate
of the serial port is
115200
, pls refer to the
following steps to connect the flight control, ground station
software.
1. Connect the flight control to airborne end. Pls pay attention
to the line sequence and the baud rate of the flight control port
must be consistent with that of the serial port.
2. Connect the ground station software to the ground end.
Note that the connection line sequence and the baud rate of
the connection port of the ground station software must be
consistent with the baud rate of the serial port.