-5- ADVISORY NOTE

 

 

Cappers is only a valves manufacturer, the following points are not part of its scope: 

 

-     Sizing of water treatment installations 

 

-     Media selection 

 

-     Valve configuration 

 

-     Components assembly 

 

-     Installation of the equipment 

 

The  components  (valve,  bypass,  distributor  tube,  SBV)  being  sold  and  delivered  separately, 
Cappers is not liable for the final result of installations made with its material; the installation must 
be done by a qualified person. 

 

 

 

 

-6- TROUBLESHOOTING

 

 

 

 

 

INCIDENTS 

CAUSES 

SOLUTIONS 

A- The system does 

not regenerate 

1) Wrong setting 

2) Used or defective 

battery(ies) 

3) Power loss 

4)  Defective  connection  with 

meter cable 

 

 

 

5) Other 

1) Check settings 

2) Replace battery(ies) 

 

3) Restore the power supply by a professional 

4) - Verify that the volume decreases when water is used 
(flow indicator runs) 

- Verify cable connection and its state. 

- Clean up or replace the turbine 
5) Contact your installer 

B- Hard water on 

outlet 

1) Salt needed 

2) Valve in “bypass position” 
3) Wrong settings 

4) Lack of maintenance 

5) Other 

1) Add salt in the brine tank 

2) Switch bypass to “service position” 
3) Check settings (Electronic board or mixing device) 

4) Follow maintenance recommendation page 21 

5) Contact your installer 

C- Brine level too high  1) Wrong settings 

2) Insufficient brine draw 

 

3) Lack of maintenance 

4) Other 

1) Check settings 
2

Clean up the breech and verify the water tightness of brine 

line 

3) Follow maintenance recommendation page 21 

4) Contact your installer 

D- Error message 

displays 

1) Failure alarm 

1) Follow indications on page 20 

E- Other 

1) Other 

1) Contact your installer 

 

 

 

 

 

 

 

 

 

 

 

19                                                                 04/04/18

Summary of Contents for INO20

Page 1: ...Model INO20 Time clock Metered SERVICE MANUAL 1 04 04 18...

Page 2: ...SCRIPTION EQUIPMENT ADJUSTMENTS P 14 2 INSTALLATION INSTRUCTIONS P 15 3 INITIAL SET UP P 16 4 USER INTERFACE P 18 5 TROUBLESHOOTING P 19 6 ERROR MESSAGES P 20 7 SPARE PARTS P 21 8 DIMENSIONS SPECIFICA...

Page 3: ...ty kg Regeneration Mode Adjustment Time clock days Metered immediate m Metered delayed m Other m Regeneration Type Down flow brining Up flow brining 1 Backwash min 1 Brining rinse min 2 Brining rinse...

Page 4: ...d be clean and neat free from lime scale and iron It should comply with current regulations Make the necessary changes to prevent troubles Connection to drain should not exceed 2 meters above the valv...

Page 5: ...3 INITIAL SET UP View Access to main features Mixing device B rine tube connexion Analysis taps Hard water inlet Treated water outlet Drain hose barb Bypass Lever 16 04 04 18...

Page 6: ...cure the assembly of the tube Tighten the clamp moderately to prevent over stress 3 6 Connect the brine tube to the valve Use a 9 52 3 8 OD tube Assembly with the quick connection system fitted on the...

Page 7: ...king stops after adjustment 4 2 DISPLAY THE REMAINING VOLUME METERED SYSTEM ONLY Press Next step to switch from time of day to remaining volume Press again to switch back 4 3 INITIATE A REGENERATION P...

Page 8: ...tore the power supply by a professional 4 Verify that the volume decreases when water is used flow indicator runs Verify cable connection and its state Clean up or replace the turbine 5 Contact your i...

Page 9: ...motor operation no short sircuit Drive force too high foreign material damaged part Inspect valve body drive force state of main seals spacers and piston foreign material Er21 to 29 blinking Valve op...

Page 10: ...Kj 34 Eo 521 25mm ou 569 27mm Verification Each year Replacement Every 5 years Inlet outlet seal kit Ref Kj 34 Eo 518 LR20 Alkaline batteries Ref Ba 20 D0 535 Replacement frequency 1 regeneration per...

Page 11: ...View remove screw to access the battery ies 9 DIMENSIONS SPECIFICATIONS SCA 19 STANDARD INO20 STANDARD 22 04 04 18...

Page 12: ...ompliant upon request Minimum pressure in service 2 Bar Maximum pressure in service 8 Bar Static maximum pressure 14 Bar Minimum temperature in service 1 C Maximum temperature in service 45 C except h...

Reviews: