62
6
)
Click on the other areas of the screen to complete the sound alarms setting;
2. On-panel operation
1
)
Select the alarm area; (different alarms can be set for different ROIs).
2
)
Press the ‘OK button to select the sound alarm button. Open the sound
alarm interface: left lane displays options: Turn off/high-temperature alarm/low-
temperature alarm; On second lane you can choose your interested attribute:
maximum temperature/minimum temperature of the region; The third lane
displays threshold for triggering alarm; Right lane displays sound effect options
for when the alarm is triggered: silence/buzzing
3
)
Use up/down direction keys to select high/low-temperature alarm in the left
lane of the interface
4
)
Use left/right direction keys to switch to the second lane of sound alarm
interface, and use up/down direction keys to select max/min temperature of ROI
5
)
Use left/right direction keys to switch to the third lane of the sound alarm
interface, and use up/down direction keys to select the appropriate threshold.
6
)
Press the ‘back’ button to complete the settings.
4.10 Palette
Click the palette set button
and enter the palettes sub-menu. You can select
the palette and set the color alarm (isotherm).