15
G3 Counters - Service Manual
1 - Air probe
2 - Evaporator probe
3 - Condenser probe
Probe Resistance
Length in decimeters
15 = 1.5m
20 = 2m
35 = 3.5m
P1 - Probe 1
P2 - Probe 2
P3 - Probe 3
1 - 1KΩ
2 - 2kΩ
4 - 10kΩ
N - NTC
T - PTC
Manufacture
Month - Year
Probe manufacturer
Probe Indentification
Probe Information
Tx
LAEx
x-xx
Sx xK xx Px
NTC10K Temperature Resistance Table
SN4K
TEMP. (°C)
R-low (KW)
R-mid (KW)
R-high (KW)
-30
109.522
113.347
117.294
-25
84.823
87.559
90.374
-20
66.27
68.237
70.255
-15
52.229
53.65
55.104
-10
41.477
42.506
43.557
-5
33.147
33.892
34.651
0
26.678
27.219
27.767
5
21.63
22.021
22.417
10
17.643
17.926
18.21
15
14.472
14.674
14.877
20
11.938
12.081
12.224
25
9.9
10
10.1
30
8.217
8.315
8.413
35
6.854
6.948
7.043
40
5.745
5.834
5.923
The probe is a type 10k NTC. The probes are identical in characteristics with the T1 and T2 identification markings and different colours being for
ease of identification and not for functional reasons. Please refer to the image below for probe identification.
Summary of Contents for ECORPO G3 EP1/2H
Page 21: ...21 G3 Counters Service Manual EP1 2L EP1 3M EP1 3L Integral Condensing Unit...
Page 22: ...22 www fosterrefrigerator com EP1 2L EP1 3M EP1 3L Remote Condensing Unit...
Page 23: ...23 G3 Counters Service Manual EP2 2H EP2 3H Integral Condensing Unit...
Page 24: ...24 www fosterrefrigerator com EP2 2H EP2 3H Remote Condensing Unit...
Page 25: ...25 G3 Counters Service Manual...
Page 26: ...26 www fosterrefrigerator com...
Page 27: ...27 G3 Counters Service Manual...