Parameter Settings

INTEGRAL

REMOTE

M

nemonic

D

efault

H

igh 

Temper

atur

e C

oun

ter S

olid D

oors

H

igh 

Temper

atur

e C

oun

ter Glass D

oor

M

ea

t T

emper

atur

e C

oun

ter S

olid D

oors

Lo

Temper

atur

e C

oun

ter S

olid D

oors

H

igh 

Temper

atur

e C

oun

ter S

olid D

oors

Lo

Temper

atur

e C

oun

ter S

olid D

oors

MDL

HYS

HYS

HYS

HYS

HYS

HYS

HYS

SPL

-2

1

1

-2

-23

1

-21

SPH

10

5

5

5

-15

5

-15

SP

3.5

2

2

-2

-23

2

-21

HY0

3

3

3

3

3

3

3

HY1

0

0

0

0

0

0

0

CMD

30

5

5

5

5

0

5

CRT

90

180

180

180

180

0

0

CT1

4

4

4

5

5

4

5

CT2

7

6

7

5

5

6

5

PB

7

5

5

5

5

5

5

IT

100

100

100

100

100

100

100

DT

0

6

6

6

6

6

6

CT

10

5

5

5

5

5

5

AR

75

70

70

70

70

70

70

CMS

100

100

100

100

100

100

100

CRS

35

90

90

90

90

90

90

CRD

15

10

10

10

10

10

10

CDS

50

60

60

60

60

60

60

CFF

60

60

60

60

60

60

60

CSS

60

60

60

60

60

60

60

CSO

1

12

12

12

12

12

12

CST

60

30

30

30

30

30

30

DFM

TAD

TIM

TIM

TIM

TIM

TIM

TIM

DFT

6

6

6

6

6

6

6

DSP

-12

-12

-12

-12

-12

-12

-12

DST

4

15

15

15

15

15

15

DMI

2

2

2

2

2

2

2

DLI

10

10

6

15

15

10

15

DTO

20

15

15

20

20

15

20

DTY

OFF

OFF

OFF

GAS

GAS

OFF

ELE

DSY

OFF

OFF

OFF

HI

HI

OFF

HI

SOD

10

5

5

5

5

5

5

DPD

0

0

0

0

0

0

0

DRN

60

0

0

90

90

0

90

INTEGRAL

REMOTE

M

nemonic

D

efault

H

igh 

Temper

atur

e C

oun

ter S

olid D

oors

H

igh 

Temper

atur

e C

oun

ter Glass D

oor

M

ea

t T

emper

atur

e C

oun

ter S

olid D

oors

Lo

Temper

atur

e C

oun

ter S

olid D

oors

H

igh 

Temper

atur

e C

oun

ter S

olid D

oors

Lo

Temper

atur

e C

oun

ter S

olid D

oors

DDM

DEF

SP

SP

SP

SP

SP

SP

DDY

2

1

2

2

2

1

2

FID

YES

YES

YES

NO

NO

YES

NO

FDD

10

10

10

-5

-5

10

-5

FTO

1

1

1

1

1

1

1

FSD

0

0

0

0

0

0

0

FCM

TMP

NON

NON

NON

NON NON

NON

FDT

-3

0

0

0

0

0

0

FDH

2

1

1

1

1

1

1

FT1

0

0

0

0

0

0

0

FT2

0

0

0

0

0

0

0

FT3

0

0

0

0

0

0

0

ATM

REL

REL

REL

REL

REL

REL

REL

ALA

-30

-30

-30

-30

-30

-30

-30

AHA

-15

-15

-15

-15

-15

-15

-15

ALR

-5

-3

-3

-3

-3

-3

-3

AHR

8

6

6

8

8

6

8

ATI

T1

T1

T1

T1

T1

T1

T1

PAD

60

60

60

60

60

60

60

ATD

90

60

60

60

60

60

60

ACC

0

0

0

0

0

0

0

ECO

YES

NO

NO

NO

NO

NO

NO

ESP

3.5

3.5

3.5

3.5

3.5

3.5

3.5

EH0

2.5

3

3

3

3

3

3

EH1

0

0

0

0

0

0

0

EPB

10

4

4

4

4

4

4

EDM

TAD

TIM

TIM

TIM

TIM

TIM

TIM

EDF

24

12

12

12

12

12

12

EDL

10

6

6

6

6

6

6

EDO

10

15

15

15

15

15

15

EDR

20

0

0

0

0

0

0

EFD

10

10

10

10

10

10

10

EFT

5

1

1

1

1

1

1

EFC

NON

NON

NON

NON

NON NON

NON

ESD

90

60

60

60

60

60

60

Summary of Contents for ECORPO G3 EP1/2H

Page 1: ...Service Manual EP1 2H EP1 2HRW EP1 2M EP1 2L EP1 3H EP1 3HRW EP1 3M EP1 3L EP1 4H EP1 4HRW EP2 2H EP2 3H Counters...

Page 2: ...your appliance Service Function Parameters Alarm Indicators Probe Data Relay Test Factory Reset Wiring Diagrams Maintenance Welcome to your interactive Foster service manual Here s how it works To re...

Page 3: ...the defrost process The worktop should not be sat or stood on Where the appliance is fitted with drawers these should not be used as a step to assist or gain height Where the appliance is fitted with...

Page 4: ...appliance produces warm air when operating normally and requires adequate ventilation The dimensions indicated are a minimum As the operating temperature has been pre set no adjustments are required A...

Page 5: ...ernal temperature and button 3 Icon Button 1 Compressor running 1 Information menu 2 Keypad locked 2 Increase value 3 Evaporator fans running 3 Standby Exit Confirm 4 Defrost in progress 4 Decrease va...

Page 6: ...store product on the base of the appliance please contact the Foster parts team to purchase the necessary shelf and spacers Always ensure air can circulate around through the stored product It is impo...

Page 7: ...e If it is required to amend the value use buttons 2 and 4 followed by button 3 to save the new value User Level Parameters Mnemonic Description SP Appliance Set Point Loc Keypad Lock tA Actual air pr...

Page 8: ...DFT accumulated only in run mode FRO Do not use DoD Do not use TAD Do not use DFT Time interval between defrosts When this time has elapsed since the previous defrost in run mode a new defrost cycle i...

Page 9: ...essor stop FT2 Timed fan stop When FT2 0 the fans remain on all the time FT3 Timed fan run When FT3 0 and FT2 0 the fans remain OFF all the time ATM Alarm threshold management NON all temperature alar...

Page 10: ...ler R1 Do not use R1F Do not use R1 Do not use FAN Output enabled for evaporator fan switching FAN Do not use DEF Output enabled for defrost switching DEF Do not use ALO Contacts open when an alarm co...

Page 11: ...ed rate of change toward setpoint actual value away from setpoint mathematical algorithm applied A E the AVG weighted average between TAir T1 and TEvaporator T2 probes T3 TAuxiliary T3 probe value whe...

Page 12: ...0 20 15 20 DTY OFF OFF OFF GAS GAS OFF ELE DSY OFF OFF OFF HI HI OFF HI SOD 10 5 5 5 5 5 5 DPD 0 0 0 0 0 0 0 DRN 60 0 0 90 90 0 90 INTEGRAL REMOTE Mnemonic Default High Temperature Counter Solid Doors...

Page 13: ...DI1 DOR NON NON NON NON NON NON D1A OPN OPN OPN OPN OPN OPN OPN LCM NON NON MAN NON NON NON NON SR1 NON FAN FAN FAN FAN FAN FAN SR2 NON NON LGT DEF DEF NON DEF RL2 NON 0 1 0 1 0 1 0 1 0 1 0 1 ACN 0 0...

Page 14: ...dealer or Foster Service tA Air probe has failed Call your authorised dealer or Foster Service to arrange for this to be replaced During this time the appliance cannot maintain an accurate temperature...

Page 15: ...522 113 347 117 294 25 84 823 87 559 90 374 20 66 27 68 237 70 255 15 52 229 53 65 55 104 10 41 477 42 506 43 557 5 33 147 33 892 34 651 0 26 678 27 219 27 767 5 21 63 22 021 22 417 10 17 643 17 926...

Page 16: ...ance Where this is not available please refer to the table below The information below is correct time of printing but is subject to change without prior notice EP1 2H 110gms EP1 2HRW 110gms EP1 2M 80...

Page 17: ...rameter DTO or the temperature set in parameter DLI is reached Where parameter TE is set to NO defrost will function on a time basis only Upon completion of the defrost cycle the appliance will resume...

Page 18: ...skets Door gaskets should be inspected periodically and cleaned where necessary with a warm damp cloth Do not use aggressive cleaning materials on the door gaskets Where door gaskets are damaged or no...

Page 19: ...19 G3 Counters Service Manual Wiring Diagrams EP1 2H EP1 2HRW EP1 3H EP1 3HRW EP1 4H EP1 4HRW Integral Condensing Unit...

Page 20: ...20 www fosterrefrigerator com EP1 2H EP1 2HRW EP1 3H EP1 3HRW EP1 4H EP1 4HRW Remote Condensing Unit...

Page 21: ...21 G3 Counters Service Manual EP1 2L EP1 3M EP1 3L Integral Condensing Unit...

Page 22: ...22 www fosterrefrigerator com EP1 2L EP1 3M EP1 3L Remote Condensing Unit...

Page 23: ...23 G3 Counters Service Manual EP2 2H EP2 3H Integral Condensing Unit...

Page 24: ...24 www fosterrefrigerator com EP2 2H EP2 3H Remote Condensing Unit...

Page 25: ...25 G3 Counters Service Manual...

Page 26: ...26 www fosterrefrigerator com...

Page 27: ...27 G3 Counters Service Manual...

Page 28: ...sterrefrigerator com Document ID code 00 570506 v2 By Appointment to Her Majesty Queen Elizabeth II Suppliers of Commercial Refrigeration Foster Refrigerator King s Lynn For service and spares For ser...

Reviews: