13
STEP 14: Connect Power Supply
SKIP THIS STEP IF EQUIPPED WITH POWER CORD.
Verify that power is turned off at the source.
• Remove junction box cover “A”.
• Locate the three dishwasher wires, (white, black
and green) with stripped ends. Insert dishwasher wires
through the small hole in the junction box “B”.
• Secure house wiring to the bottom of the junction box
with a strain relief “C”.
• Use wire nuts to connect incoming ground to green,
white to white and black to black “D”.
• Replace junction box cover “E”. Check to be sure that
wires are not pinched under the cover.
STEP 15: Pre-Test Checklist
Review this list after installing your dishwasher to avoid
charges for a service call that is not covered by your
warranty.
• Check to be sure power is OFF.
• Open door and remove all foam and paper packaging
• Locate the Owner’s Manual in the literature package.
• Read the owner’s manual for operating instructions.
• Check door opening and closing. If door does not
open and close freely or tends to fall, check spring
adjustments. See Step 1.
• Check to be sure that wiring is secure under the
dishwasher, not pinched or in contact with door springs
or other components. See Step 9.
• Check door alignment with tub. If door hits tub, evel
dishwasher. See Step 10.
• Pull lower rack out, about half way. Check to be sure
it does not roll back or forward on the door. If the rack
moves, adjust leveling legs. See Step 10.
• Check door alignment with cabinet. If door hits cab
inet, reposition or relevel dishwasher. See Step 10.
• Verify water supply and drain lines are not kinked or in
contact with other components. Contact with motor or
dishwasher frame could cause noise. See Step 8.
• Turn on the sink hot water faucet and verify water
temperature. Incoming water temperature must be
between 120°F and 150°F. A minimum of 120°F tem
perature is required for best wash performance. See
“Prepare Hot Water Line,” page 5.’
• Add 2 litres of water to the bottom of the dishwasher
to lubricate the pump seal.
• Turn on water supply. Check for leaks. Tighten con
nections if needed.
• Remove protective fi lm if present from the control
panel and door.
Installation Instructions
If house wiring is not 2-wire with ground,
a ground must be provided by the installer.
When house wiring is aluminum, be sure to
use cUL/UL Listed anti-oxidant compound
and aluminum to-copper connectors
Warning