5.3.
Sensitive element laying
FORTEZA OFFER
The kind of laying depends from the fence type. If Tribo M is used for non-standard
fences we offer first to try it working with this kind of fence. Prepare a sensitive
element about 10 meters and install it on the fence (1 or 2 segments) in your chosen
way.
1)
Connect to Tribo-M unit and set up it’s sensitivity.
2)
Test Tribo-M sensitivity.
3)
Test Tribo-M for noise immunity (wind, vibration, shocks).
4)
If Tribo-M detects an intruder and don’t give alarms from noises - this variant of
laying can be used on all segments of this fence. Sensitivity will be the same for all
distance.
Prior to laying, proceed as follows:
•
Arrange the sensitive element along the fence inside without bights; make sure it is free of mechanical
damages and the sensitive element ends are protected from moisture ingress.
To lay the sensitive element, proceed as follows:
•
proceed according to the design documents;
•
make sure the ambient temperature is not less than minus 10
о
С;
•
laying the sensitive element along the fence, make sure, that the radius of its bend is 120 mm minimum;
•
stress points should be made with plastic ties ( 140 x 3.5 mm) Nylon 6.6 self-extinguishing V2 UL94.
Temperature range -40/+100, distance between stress point is from 20 up to 45 cm, depends from a
fence type ;
•
the parts of sensitive element must be connected over a connection sleeve only.