Freezing tubes in the boiler supply line in winter time,
bubbles in the water line tubes, broken water filter,
faulty water pump.
Damaged detergent tanks, damaged water tank.
No pressure in the boiler, or to the contrary: the display
shows pressure, while there is little steam at hose
outlets; boiler heats up insufficiently and too long.
Stop the machine using the red button. Empty the boiler by opening the water drain valve and draining the steam
and rest of water. Open the water tank’s water drain valve in order to empty the water tank according to procedure
described in section “Switch-off procedure” points 10-12.
Open the water drain valves and detergent tanks Fig. 2 element 5 / 6 / 7. Empty the tanks from water and detergent
at temperatures below 0°C.
Perform the boiler descaling procedure using the
VAPOR preparation. Switch off the machine, connect
all cleaning and washing hoses to quick connector
properly. Washing hose as in Fig. 2 element 2, Cleaning
hoses as in Fig. 2 elements 3 and 4. Empty the boiler
and the water tank by opening drain valves (Fig. 2,
element 9). When the machine is stopped and emptied,
unscrew the coupling that connects the four-terminal
network with the copper tube (Fig. 3, element 1, and Fig. 4
element 1). Using a syringe, inject some VAPOR into
the copper tube. Wait till it starts to boil, and slowly
add small portions in order to thoroughly dissolve
the mineral deposit inside the tube. After approx.
20 minutes, re-connect the coupling to the four-terminal
network. Close the boiler drain valve and the water tank
drain valve. Pour approx. 1-2 litres of VAPOR into the
water tank. Start the machine, wait till the water pump
sucks the entire VAPOR in from the water tank.
As soon as the machine stops and begins to squeal, add
water into the tank. Pour the water in until the machine
starts both the burner and the boiler.
Replace water filter, replace water pump.
Replace tanks and level probes in fluid tanks.
This indicates that the machine has been left in freezing
conditions at temperature below 0°C without having
emptied the boiler and the water flow line.
This indicates that the machine has been left in freezing
conditions at temperature below 0°C without having
emptied water and detergent tanks.
Scaled boiler, scaled steam outlet system and / or
cleaning / washing hoses.
1 problem
2 problem
3 problem
Diagnosis
Diagnosis
Diagnosis
Prevention
Prevention
Solution
Solution
Solution and prevention